Description
Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 6 Sources Sought Synopsis Only The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (hubzone, 8(a), small, small disadvantage, veteran owned small business (VOSB), service-disabled veteran owned small business (SDVOSB), or large business) relative to NAICS 334516 with size standards of 1,000 employees. Note that if VA s pending market research establishes that two or more VOSB or SDVOSB, who are certified in VA s Vendor Information Pages (VIP) site https://www.vip.vetbiz.gov/, can perform the project, VA will set aside the underlying solicitation per 38 U.S.C. §8127. Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Synopsis, a solicitation announcement may be published on SAM, and/or GSA eBuy. Responses to this Sources Sought Synopsis are not considered adequate responses to the solicitation announcement. General Requirements: The Department of Veterans Affairs (VA), Phoenix VA Health Care System, has a need for a biomedical engineering analyzer. The requirement is for brand name or equal to. Salient Characteristics: Item # Description Qty (ea) Country of Origin 398A912 Electro-Surgical Analyzer 2 Must be portable/battery powered Must have integrated oscilloscope Must have onscreen power profile analysis Must have onboard automation and data capture Must have full color user-interface Must be able to test cut AND coagulation feature from a remote foot switch control Must have high current test capability up to 6 Ampere RMS Must have a Non-inductive load bank from 0 5115 Must be capable of variable load AND fixed load Must have power range: 0-500W Must have current range: 0-6000mA Must have voltage range: 0-700V Must have crest factor range: 1.4-20 Must have bandwidth, with load bank, 30-2.5MHz Must have interference frequency filter: 100Hz high pass filter Must have all IEC 60601-2-2 leakage tests Participating Healthcare Facilities: VISN 22 West VA Long Beach Healthcare System 5901 East 7th St, Long Beach, CA 90822 In response to this announcement, please complete the information below: Company: Address: Contact Name: Phone No: Email: DUNS: Business size information Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HubZone Woman Owned Certified Service-Disabled Veteran Owned Small in Vetbiz.gov Certified Veteran Owned Small Business in Vetbiz.gov Large Business Other:____________ Are you a FSS/ GSA Contract Holder of the requested item(s)? If yes, provide the information below. Yes No FSS/ GSA Contract Number Effective Date / Expiration Date Does your company manufacture the requested product(s)? If no, answer the questions below. Yes No Does your company exceed…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)