Description
Amendment 0001 is hereby issued to incorporate the following changes: 1. Government's consolidated responses to vendor questions. 2. Post Site Visit Meeting minutes and sign-in sheet. 3. Extend Period of Performance from 60 days to 235 days. 4. Add FAR Clause 52.222-90 Addressing DEI Discrimination by Federal Contractors. 5. Update tailored version of FAR Clause 52.212-4 Terms and Conditions - Commercial Products and Services: 52.212-4 is hereby tailored IAW FAR Dev 12.205(b)(1)(ii): (b)Inspection/Acceptance IAW FAR Dev 52.246-12. (d)Changes. IAW FAR Dev 52.243-5.(i)Payment. Retain (i) payment, supplement with FAO-0023 Progress Payment. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with FAR part 12 in conjunction with FAR Part 36. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued. This acquisition IS set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Solicitation number 15BBNF26Q00000051 is issued as a request for quotation (RFQ), for: The Federal Bureau of Prisons, Field Acquisition Office, intends to issue a solicitation for the following requirement: FCI Marion intends to make a single award to a responsible entity that will provide all necessary equipment, labor, materials, and incidentals necessary to remove the existing 4,800 MBTU summer boiler and install a new 7,500 MBTU watertube boiler system, in accordance with the project specifications and all applicable codes. The work includes complete removal and disposal of the existing boiler, including disconnection and removal of associated steam piping, feedwater piping, blowdown piping, safety valve vent, electrical connections, and a section of the existing stack. The contractor shall supply, deliver, and install a new Cleaver Brooks M5‑700‑7500‑150St (or equivalent) natural‑gas‑fired watertube boiler with 7,500 MBTU input / 6,000 MBTU output capacity, 0.95" tube wall thickness, and 100 psig operating pressure. Installation includes all required piping, valves, gauges, regulators, safety devices, low‑water cutoff, stack components, gas train modifications, feedwater connections, and electrical reconnections. The contractor shall install new steam spool pieces, a non‑return valve, a 4" stop valve, and tie‑in to the existing steam distribution system. Work also includes installation and testing of the HAWK actuator system, commissioning, boil‑out procedures, operational testing, and verification of all safety and control functions. All work must be completed without altering existing walls or doors and must comply with all Federal, State, and local codes…
Classification
Place of Performance
Contracting Office
Contacts