Description
This is a combined synopsis and solicitation for commercial service prepared in accordance with (IAW) format in Federal Acquisition Regulation (RFO) part 12, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a separate written solicitation will not be issued Requirement Title: Giant Voice System Maintenance Solicitation Number: FA483026Q0027 Solicitation Issue Date: 8 May 2026 Solicitation Updated: 13 May 2026 (only POC's and CO listed have been updated on solicitation) Response Deadline: 2:00PM EST on 18 May 2026 Point(s) of Contact: SSgt Samantha Elia, Mrs. Amanda Richardson Contracting Officer: Mrs. Amanda Richardson Interested vendors are advised to review the attached Combined Synopsis/Solicitation, SF1449, and Statement of Work (SOW) for complete requirement details, submission instructions, and applicable terms and conditions SCOPE Moody AFB is seeking sources capable of providing the maintenance and sustainment of Emergency Mass Notification System (EMNS) Giant Voice (GV). The work entailed will provide for properly provisioning a preventive maintenance schedule and actions to ensure the serviceability of the system. OBJECTIVES Conduct one annual Preventive Maintenance Inspections and system upgrades at Moody AFB. All visits shall be accomplished by technicians proficient in the type of work for inspecting and testing the entire EMNS system consisting of the following: 3 base station locations and equipment: Command Post Alternate Command Post 23 CS/SCOTR Shop EMNS power supplies at each location. Perform diagnostic testing at each siren location, which includes performing a quiet test and inspecting the condition of each siren pole and antenna. Perform functional testing – Note: Sounding of the warning sirens is a necessary part of inspection procedures, to include public address and ATHOC. Note: Moody Command Post must have previously obtained approval to sound the sirens in advance of technicians arriving on base. Perform diagnostic tests REACT 5000 and associated computers. Ensure latest software upgrades are included and installed on each computer throughout the year. All EMNS poles and Sirens (Quantity 11) Verify proper grounding at all siren sites. Inspect interior and exterior of cabinet for corrosion. Ensure inside of cabinet is clean and dry. Load-test all batteries installed in siren battery cabinets to ensure they measure at least 25 volts DC at the RTU's main circuit board. Check charger's DC voltage located on main circuit board voltage should measure approximately 30 volts DC. Ensure all wires and circuit connections are secure and seated firmly. Ensure speakers are free of animals and nesting materials. Inspection of all radios installed within each siren control cabinet, its antenna and associated antenna cable, and all base station equipment. Verify proper grounding at all sites. Inspection of all radios installed …
Classification
Place of Performance
Contracting Office
Contacts