Description
Farmington, Minnesota January 20, 2026 SCOPE OF WORK A. General Requirements: 1. The Contractor shall design and provide a complete service-oriented water treatment program for all boiler systems, cooling towers, all heating water circulating systems, and all chilled water systems that will accomplish the following results: a. Reduce fuel and electrical consumption through improved heat transfer efficiency by minimizing scale, corrosion, fouling and microbiological growth. b. Minimize the repair and maintenance costs associated with replacement and cleaning of equipment due to scale, corrosion, fouling and microbiological growth. c. Provide professional knowledgeable and involved service personnel to ensure program success. d. Accurately monitor program results and provide appropriate recommendations with quantifiable personnel. e. Provide thorough training to all building Environmental Technicians on the implementation and control of the program. 2. The Contractor shall furnish all chemicals, testing reagents and equipment to properly treat all applicable systems, as indicated above. B. Specific Requirements The Contractor shall be responsible for all the following areas: Program Goals : The water treatment program will provide scale and corrosion protection for condenser water system, cooling towers, chillers and chilled water systems, deaerator, condensate lines, and closed hot water loops. Contractor Commitment : Contractor's chemical program and consulting service are to produce clean heat transfer surfaces, which are substantially freed of scale, sludge, deposits, corrosion, pitting and biological growth when treatment is administered in accordance with Contractor's directions and recommendation. Representative Experience : The Contractor will provide sufficient personal including a direct supervisor to represent the company in dealing with the FAA. All representatives shall be full-time employees of the Company. Representatives shall be familiar with all aspects of water treatment and have as a minimum a Bachelor of Science degree in chemistry or chemical engineering from accredited university. Only these individuals shall represent the Contractor regarding services for this Service Agreement. Service Level and Response Time : A representative shall visit the facility every two weeks. All chemicals and products shall have the capability of ordering on-line. Delivery to the site shall be no greater than 24 hours from the time the order is placed. At minimum, the representative will conduct independent tests, review the facility's monitoring and control program and will submit written reports on program statue/trends with recommendations for improvement. All trucks coming onto the FAA site shall be inspected on arrival and on exiting the facility. Trucks leaving the facility shall be empty, unless special approval is obtained from the FAA. Trucks shall only carry chemicals and/or products for the FAA facility. Distribu…
Classification
Place of Performance
Contracting Office
Contacts