Description
Description This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C24226Q0340 is issued as a request for quotation (RFQ) for a Physical Access Control System (PACS) and the Intrusion Detection Systems (IDS). This acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular number 2026-01, effective date of 03/13/2026. This solicitation is set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The associated North American Industrial Classification System (NAICS) code for this procurement is 334290, with a small business size standard of 800 employees. The FSC/PSC is 6350. All interested parties shall provide quotations for the following: Statement of Work 1. Background a. The Physical Access Control System (PACS) and the Intrusion Detection Systems (IDS) at both the Montrose and Castle Point Veterans Administration Medical Centers (VAMCs) are past their end-of-life cycles. While the systems are still partially operational, the PACS system server has failed, and the IDS components are no longer supported by the manufacturer. In the current state, the VAMCs physical security operation is vulnerable, and further systems deterioration is inevitable. b. The VAMC's Electronics, Engineering and Police leaders have collaborated on a strategy to replace the PACS and IDS systems in a multi-year, phased approach while maintaining the VAMC health care security operations. The strategy aims to integrate the Hudson Valley Health Care security systems to work together efficiently, to leverage data analytics, and to bolster access control and intrusion capabilities. The strategy is also forward thinking to ensure the PACS will integrate with future video surveillance system (VSS) upgrades. 2. Physical Access Control System a. Contractor will provide for installation of all Software House iStar G2 Controllers. b. Customer to provide direct connected power to new controllers, and server location. c. Contractor to provide Network Connections from the G2 Controllers to the network switch for server for connectivity. Contractor to provide cable and install access control readers as shown on plans. d. Access control doors will include a card reader, request to exit, contact and a connection to electric locking hardware. i. Complete all panel and field terminations. Contractor will clearly mark all cables and panels in accordance with the attached Site Drawings. ii. Contractor will clearly post the appropriate PACS …
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)