Description
Notice of Intent to Sole Source LOCATION: Department of Veterans Affairs (VA), VISN 10 Chillicothe VA Medical Center 17273 State Route 104 Chillicothe, OH 45601 SUBJECT: Intent to Sole Source Water Well Field and Equipment Repairs (Pump Replacement, Well Rehabilitation, Controls and Communications Upgrades) NOTICE NUMBER: 36C25026Q0527 PSC CODE: J043 Maintenance, Repair, and Rebuilding of Equipment Pumps and Compressors NAICS CODE: 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance Small Business Size Standard: [Insert SBA size threshold] DESCRIPTION OF REQUIREMENT The Chillicothe VA Medical Center requires a specialized contractor to provide all labor, materials, equipment, transportation, and supervision necessary to: Test and video inspect two existing wells Perform staged mechanical and chemical rehabilitation of wells Remove existing pumps, motors, drop pipe, and pitless assemblies Furnish and install two new submersible pump/motor assemblies and accessories capable of delivering 350 GPM at 60 75 PSI Replace meters, 6 inch check valves, and gauges Install VFDs, alternating control, and SCADA Install communications equipment and wiring Install pressure sensing and logic Perform complete system startup and testing Provide all required O&M documentation Provide a 36 month warranty for installed equipment and workmanship PLACE OF PERFORMANCE Chillicothe VAMC Well Field located east of State Route 104, approximately ½ mile from the Main Boiler Plant. PERIOD OF PERFORMANCE Not to exceed 90 calendar days from issuance of the Notice to Proceed (NTP). ANTICIPATED CONTRACT TYPE Firm Fixed Price (FFP) ESTIMATED MAGNITUDE [Insert: e.g., Below the Simplified Acquisition Threshold or a range if permitted] AUTHORITY This acquisition is being conducted under FAR 6.302 1 Only One Responsible Source. JUSTIFICATION SUMMARY Based on market research and historical technical findings, Moody s of Dayton is the only responsible source with the unique qualifications necessary to perform the integrated well field rehabilitation, pump replacement, communications, and SCADA/VFD control work required by the Chillicothe VAMC. Moody s possesses: Site specific diagnostic history Familiarity with well depths, pitless adapters, and pump configurations Expertise integrating with existing control/SCADA systems Immediate availability to perform the work without operational disruption No other vendors identified possess equivalent site specific knowledge or the ability to meet the VA s performance schedule. THIS IS NOT A REQUEST FOR COMPETITIVE QUOTES However, any firm believing it can fully meet this requirement may submit a capability statement demonstrating clear and convincing evidence of its ability to perform the work within the required timeframe. RESPONSE INSTRUCTIONS Submit capability statements no later than 4:00PM on May 1, 2026 to: Matthew Curtis Contract Specialist Email: matthew.curtis1@va.gov Submiss…
Classification
Contracting Office
Contacts
Attachments (1)