Description
The Black Hills Healthcare System requires Generator Testing, Maintenance, and Repair Services in accordance with the draft Statement of Work (SOW) below. This is a sources sought/proof of capability solicitation looking for vendors to perform the services per the SOW for market research purposes. No award of a contract will be made from this announcement. If you are a vendor that can complete the work described in the SOW with competitive pricing, please send your contact and organization information with a descriptive proof of capability to: Joey Bloomer, joseph.bloomer@va.gov on or before May 26th, 2026. Only emailed responses will be considered. Additionally, provide answers as appropriate to the following questions in the table below with your response to this sources sought. Failure to respond to the following questions may affect the acquisition strategy. 1. Identify your organization's socio-economic category. 2. State whether any of the requested services may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.). 3. State if subcontracting is contemplated for this requirement and what percentage of the work will be subcontracted and for what tasks. Â *If applicable, VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small-Businesses or Service Disabled Veteran Owned Small-Businesses.* *If applicable, FAR 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Businesses.* STATEMENT OF WORK Semi-Annual VA BHHCS Emergency Generator Testing and Maintenance 1. SCOPE Provide semi-annual preventive maintenance inspections and services on emergency generators at the VA medical Centers at Ft Meade and Hot Springs, South Dakota and VA clinic in Rapid City (if mobile units are in place there). The Fort Meade campus has a 12470-volt primary system that includes various secondary voltages and both normal and emergency power sources. Inspection reports from attachments A & B to be provided to facilities POC s within 30 days of service. 2. CONTRACT POC S FOR SCHEDULING WORK AND COORDINATION ARE AS FOLLOWS: Fort Meade VAMC: Delane Erickson, Operations Supervisor, Phone: 605-720-7134 Hot Springs VAMC: Dan Cerveny, Maintenance Supervisor, Phone 605-745-2268 3. EQUIPMENT Fort Meade Emergency Generator equipment included in the scope of work is as follows: A. Bldg. 113 Emergency Generator Manufacturer: Cummins/ 750 KW/ 480V Generator Model; DQCB-1641706 / Serial Number: K160128689 Engine Model: QSK23G7 / Serial Number: 85002334 B. Bldg. 148 Emergency Generator Manufacturer: Cummins/ Onan/ 125 KW/ 480V Generator Model: DSGAB- 1321187 / Serial Number: B130456361 Engine Model: QSB7 G5 NR3 / Serial Number: 73494119 C. Bldg. 145 Emergency Generator Manufacturer: Cummins/ 250 KW / 208…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)