Description
The purpose of this sources sought notice is to conduct market research and identify potential sources of commercial equipment/services that satisfy the Government's anticipated needs. BACKGROUND The Structures Group in the Engineering Laboratory at the National Institute of Standards and Technology (NIST) performs research to enhance the ability of structures in the United States to 1) resist damage from various hazards (e.g., blast, wind, and seismic hazards) and 2) recover from and adapt to hazards that result in damage. To this end, the Structures Group is expanding upon a recently completed experimental research effort that focused on mitigating disproportionate collapse of buildings in the United States. The final phase of that effort involved experimentally testing precast concrete beam-column connection assemblies produced at 5/8 scale and that featured novel connection concepts developed by NIST researchers in collaboration with an industry review committee of Precast/Prestressed Concrete Institute (PCI) members. These assemblies were subjected to static pushdown testing that simulated a column-removal scenario for disproportionate collapse applications. The test results showed that the connection concepts were viable for use in precast concrete construction to achieve robust performance against disproportionate collapse. The current experimental research effort involves structural testing of full-scale precast concrete beam-column connection assemblies under forces that simulate those imposed by earthquakes. The assemblies will feature the previously tested connection concepts to establish whether these connections can perform adequately under various hazards acting asynchronously. Requirements: NIST is seeking information from sources that may be capable of providing a solution that will achieve the objectives described below: Line Item 0001: Stainless Steel Load Washer Quantity: 6 The load cell washers shall meet the following minimum requirements: Through hole inner diameter greater than 2.5 in. and less than 3 in. Outer diameter of the load cell body less than 6 in. Load cell height less than 6 in. Rated compressive capacity of at least 225 kip/1000 kN Integral electrical cable connection with a cable length of at least 9 ft. Stainless steel construction Ingress Protection (IP67) rating Excitation voltage between 2 and 12 VDC HOW TO RESPOND TO THIS NOTICE In responding to this notice, please DO NOT PROVIDE PROPRIETARY INFORMATION . Please include only the following information, readable in either Microsoft Word, Microsoft Excel, or .pdf format, in the response: Submit the response by email to the Primary Point of Contact and, if specified, to the Secondary Point of Contact listed in this notice as soon as possible, and preferably before the closing date and time of this notice. Please note that to be considered for award under any official solicitation, the entity must be registered and “active” in SAM at the time of solicitation …
Classification
Place of Performance
Contracting Office
Contacts