Description
Sources Sought Notice DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to fulfill a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 8, is conducting market research to identify potential sources which can provide the following supplies in support of the Bay Pines, VA Health Care System. As part of efforts to expand Radiation Oncology, this system must be compatible with the Varian TrueBeam linear accelerator. It must have interoperability with Varian Linacs via MMI in order to interface directly for auto beam hold capabilities, send to couch features, auto patient import and more. The Miami VAMC is currently using the VisionRT s Surface Guided Radiation Therapy (SGRT) in one vault and seeking to add another system to better serve the Veteran population. The video module of the system shall allow for a multi-angle, real-time view of the patient's overall alignment relative to their reference position during setup and monitoring by using an outline of the reference surface and a live video stream of the patient. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources who can provide a Brand Name or Equal system to AlignRT Surface Guided Radiation Therapy (SGRT) system. Functions to be performed: Surface Guided Radiation Therapy (SGRT) system that allows real-time tracking of patients before and during radiation therapy. Functions must use contact-free techniques to track patients skin surfaces with sub-millimetric accuracy ranging below 0.5mm in all six degrees of freedom. Ensures radiation is only delivered when patients are correctly positioned. System must ensure accurate and reproductible patient setup and monitoring during dose delivery. System must have the ability to automatically pause treatment due to expected and unexpected patient adjustments made during dose delivery and treatment. Shall be compatible with Varian TrueBeam Linear Accelerator: Shall be completely integrated with Varian TrueBeam Linear Accelerator through MMI interface for GATING (Beam Hold) and applying directly 6DOF (Degrees of Freedom) couch shifts to the linac in case of patient motion, assuring the safe and accurate delivery of radiation. System shall be able to perform the following therapies and examinations: DIBH (Deep Inspiration Breath Hold) General Breast SRS (Stereotactic Radiosurgery) SBRT (Stereotactic Body Radiation Therapy) Head and Neck Breath Hold SBRT Sarcoma Prostate Software and Interfacing Requirements: Shall be compatible with Varian TrueBeam Linear Accelerator: Shall be able to be co…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)