Description
SOURCES SOUGHT: THIS IS NOT A NOTICE OR REQUEST FOR PROPOSAL BUT FOR INFORMATIONAL AND PLANNING PURPOSES ONLY! This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost in developing information provided to the Government. If a solicitation is issued, it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from responses to this announcement. This Sources Sought is only intended to identify potential sources for the purpose of market research. The draft Statement of Works (SOW) describes only the three currently contemplated scopes of potential requirements and may vary from the scope of the requirement in a final SOW included in any RFP. The Sources Sought number is FXSB 26-6837 and shall be used to reference any written responses to this Sources Sought. The additional two requirements FXSB 26-6670 and the third one FXSB 26-7337 are being added to this Sources Sought due to the similarity and magnitude. The anticipated North American Industry Classification Systems (NAICS) code is 238160, Roofing Contractors with a size standard for the proposed NAICS of $19M. Business Status: The Government is interested in all Small Businesses that are capable of meeting this requirement, including 8(a), HUBZone, SDVOSB, WOSB, VOSB, and general Small Businesses. REQUIREMENT: FXSB 26-6837 Repair Replace Hangar Roof B11525 Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that's approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new. REQUIREMENT: FXSB 26-6670 Repair Replace Hangar 3 Roof B10571 Building 10571 is a one-story, 68,986 square feet (SF) building framed primarily out of steel and cast-in-place concrete. The building was originally constructed in the early 1940s and is a historic property eligible for listing on the National Register of Historic Places. The main open space is 200-ft by 229-ft with a high ba…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (3)