Description
Amendment 0005 - This amendment makes the following changes: - Descope - Due to funding limitations, the Great Wall of Buckeye site is removed from the base items on the SOI. Any reference to this site throughout any attachments is hereby deemed not a part of any resulting contract. - SOW paragraph 1.7 START DATE is changed to May 18, 2026. - SOW paragraph 1.8 CONTRACT TIME is changed to 344 Calendar Days; the POP end date remains 4/26/2027. - The response date is changed to May 1, 2026. The time remains 12:00 PM MT. No, other changes are made. See the two newly attached documents: 1.5 1240LT26Q0016 - Amendment 0005 3.2 SOI_GAOA South Zone Fence Replacement Update 02 ------------------------------------------------------------------------------------------------------------ Amendment 0004 - This amendment makes the following clarifications: Updated to add CO signature. - There are some discrepancies that have been identified within the solicitation. The attached questions and answers address those discrepancies with instruction as to what information takes precedence. These answers will be made a part of any resulting contract. The supporting documents will be adjusted as identified within this amendment. - The response date is changed to April 3, 2026. The time remains 12:00 PM MT. See the newly attached amendment "1.4 1240LT26Q0016 - Amendment 0004". ------------------------------------------------------------------------------------------------------------ Please note that the date offers are due is being extended to 4/3/2026. It is anticipated that an additional amendment may be necessary. This solicitaiton is currently being reviewed and will be updated once that decision is made. ------------------------------------------------------------------------------------------------------------ Amendment 0003 - This amendment makes the following clarifications: - There is a discrepancy between the SOW Section 3.3 and Attachment 8. Wood Rail Diagram concerning the size of bolts to be used. The SOW supersedes the attachment in this case and 3/8" bolts should be used for construction. - The SOW Section 7.7 specifies gate requirements. The number of gates is given in previously answered and posted questions. No gates require replacement with new hardware. Any gate that is found in place of a section of fence to be rebuilt, should be reused on the newly erected fence. This is incidental to the fencing line items. - The KMZ file notes a site named "Stuart". This site is not included in the solicitation. - The response date remains unchanged as March 26, 2026. The time remains 12:00 PM MT. No, other changes are made. ------------------------------------------------------------------------------------------------------------ Amendment 0002 - Schedule of Items updated. No new work added, but attachment 3. SOI_GAOA South Zone Fence Replacement is updated to 3.1 SOI_GAOA South Zone Fence Replacement Update 01. The following changes have been made: - Mobili…
Classification
Place of Performance
Contracting Office
Contacts