Description
Combined Synopsis-Solicitation for Commercial Products and Commercial Services Effective Date: 04/18/2025 Revision: 02 Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-04. This solicitation is set-aside for SDVOSB The associated North American Industrial Classification System (NAICS) code for this procurement is 333415, with a small business size standard of 1250 Employees. The FSC/PSC is J041. The White River Junction VAMC located at 163 Veterans Drive is seeking a qualified vendor to provide a Dietetics Walk-In Freezer Replacement IAW the SOW. All interested companies shall provide quotations for the following: Supplies/Services ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 Dietetics Walk-In Freezer Replacement IAW the SOW Period: Base 1.00 EA __________________ __________________ STATEMENT OF WORK (SOW) Dietetics Walk-In Freezer Replacement Department of Veterans Affairs White River Junction VAMC Project Scope The White River Junction VA Healthcare System requires the services of a qualified firm to upgrade the refrigeration components of the dietetics walk-in freezer. It has been determined that the cabinet of the existing freezer is in sufficient condition, therefore entire box replacement is not necessary. Contractor shall ensure that the removal process of the old components does not damage the structure of the walk-in freezer. Condenser is housed inside an enclosure on the roof. Use of a crane will be necessary for the safe removal of existing equipment, and proper installation of the new equipment. Contractor will need to cut into enclosure to perform work. Contractor will be responsible for disassembly and reassembly of structure. Current structure is made of wood with metal siding. Contractor shall be responsible for confirming that the cooling capacity for the system is sufficient. Current capacity is 36,410 BTU. Contractor shall be responsible for all electrical attached to this project. Voltage of current equipment is 208/230. This will include confirming the new equipment does not exceed the available amperage. If new equipment does exceed the available amperage, contractor shall work with onsite facilities staff to find solutions or choose other equipment. Contractor shall provide and install a refrigerant that is appropriate for low-temperature applications and meets all current indus…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (5)