Description
U.S. GOVERNMENT General Services Administration (GSA) seeks to lease the following space: State: Ohio City: Cleveland Delineated Area: - North: Front Ave to W 9th St to Hwy 2 - East: Hwy 90 - South: Hwy 90 - West: Cuyahoga River Minimum Sq. Ft. (ABOA): 105,557 Maximum Sq. Ft. (ABOA): 110,835 Space Type: Office and Related Space Parking Spaces (Total): 36 Parking Spaces (Reserved): 18 secure, structured parking spaces must be designated for Government use only. (GOVs) 18 surface or structured for parking spaces. Must be covered spaces located immediately on the Premises. (Visitors) Full Term: 180 months Firm Term: 156 months Additional Requirements: - The Government requires two (2) separate and distinct blocks of space: BLOCK 1: 103,263/ABOA - 108,426/ABOA If the entire space cannot be located on one contiguous floor location, contiguous floors are required and must provide a secure pathway (route) for connectivity between government spaces. Wiring must be secured in metal conduit or risers with bushings. This space shall allow for a public-facing, daily visitor operation. BLOCK 2: 2,294/ABOA - 2,409/ABOA Contiguous space on one floor. (1st or 2nd floor only) Approximately 75 ABOA SF of this space will be used as “Bunker Storage Space” for K-9 training which can be located either within the Space or located within the Premises. The approximate weight of this Bunker Storage is 650 lbs. Offerors are encouraged to determine if additional floor support is necessary to support this requirement. Be advised that this Space shall not be situated immediately adjacent to schools or religious institutions within the same Premises. Ensure that all proposed offered spaces strictly adhere to these proximity restrictions. This space shall allow for armed Federal Law Enforcement employees. This space shall allow for canine officer(s). - The Government requires 24/7 access to offered space and parking. - --- Mixed-use space is not allowed. - For effective space utilization, a minimum of 20'-0” o.c. between structural elements (columns, core, curtain wall, etc.) is required. - General office space must have a ceiling height of a minimum 9'-0” AFF. Ceiling Heights in the MDF, IDF or other equipment rooms shall be a minimum of 9'-0” clear and have sufficient space above the ceiling for independent HVAC units, ducting, cable trays, or other necessary devices. - Accessibility for wheelchair visitors, including ramps and/or elevators to facilitate ease of access from parking to entrance, is required. - The offered Premises must have a loading dock with access to a freight elevator. Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the terms of the Lease. A fully serviced lease is required. Offered space shall not be in the 1-percent-annual chance floodplain (…
Classification
Contracting Office
Contacts
Attachments (1)