Description
*= Required Field This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01. This solicitation is set-aside for SDVOSBs. The associated North American Industrial Classification System (NAICS) code for this procurement is 238210, with a small business size standard of $19.0 million. The FSC/PSC is J061. The Department of Veteran Affairs (VA) Central Western Massachusetts Medical Center located at 421 North Main St. in Leeds, MA 01053 is seeking to purchase services for electrical repairs as outlined in the Performance Work Statement: 04/08/2026 PERFORMANCE WORK STATEMENT VA Medical Center Leeds, MA B65 Switch 1 Repair Electrical Repair Service, VACWM, Leeds, MA GENERAL: This is a non-personnel services contract to provide electrical repairs and service. The Government shall not exercise any supervision or control over the contract service providers performing the services herein. Such contract service providers shall be accountable solely to the Contractor who, in turn is responsible to the Government. Description of Services/Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, lockout/ tagout, supervision, and other items and non-personal services necessary to perform electrical repairs and service as defined in this Performance Work Statement (PWS) except for those items specified as government furnished property and services. All shutdowns and deenergizing of equipment shall be the contractor s responsibility. The contractor shall meet the standards in this contract. The contractor shall show a minimum of 5 years of successfully completed experience in fixing and repairing medium voltage equipment, testing medium voltage equipment, and medium voltage LOTO. Installing new medium voltage equipment will not be considered as repair experience. Background: The Leeds campus has experienced a failed medium voltage electrical switch. This requires repair under the NFPA 70B and VA 1028 directive to have a safe and maintained electrical system. Objectives: Switch 1 requires internal insulators to be replaced and tested. Switch 1 is a park switch model number PM255-2-2-2-LF. Scope: After award, but prior to the start of any field work, the contractor shall contact the Project Engineer/Manager (i.e. COR) to review proposed methods and plans for completion of work and to review infection contro…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (3)