Description
A market survey is being conducted to determine if there are a reasonable number of interested small business concerns to set this future project aside for them. If your firm is a Small Business, certified HUBZone, 8A, Woman-Owned Small Business or Service-Disabled Veteran Owned Business, and you are interested in this project please respond appropriately. Project Location: Louisville District Lock & Dams Markland Lock & Dam 2760 US 42 West Warsaw, KY 41095 McAlpine Lock & Dam 805 North 27th Street Louisville, KY 40212 Cannelton Lock & Dam 5821 East State Road 66 Cannelton, IN 47520 Newburgh Lock & Dam 6877 State Road 66 Newburgh, IN 47630 John T Myers Lock & Dam 16501 Raben Road Mt. Vernon, IN 47620 Smithland Lock & Dam 1401 Smithland Dam Road Brookport, IL 62910 Olmsted Lock & Dam 634 New Dam Road Olmsted, IL 62970 Project Description: Work to be performed is Maintenance and Inspection of multiple elevators across the Louisville District, please see project sites listed above. Work included: Routine: Routine maintenance which will consist of a lube and exam service to each elevator will be accomplished quarterly with no interval to exceed (3) months from the last date of service. Maintenance and inspections shall be accomplished in accordance with (IAW) the elevator manufacturers' inspection criteria and applicable requirements of ANSI A17.1, ANSI A.17.2 and ANSI A 17.3. Periodic (No-Load) Inspection: Periodic – no-load inspections will be accomplished during the first quarter of every year during the performance of routine maintenance and inspection. Inspections will be accomplished in accordance with (IAW) the elevator manufacturers' inspection criteria and applicable requirements of ANSI A17.1, ANSI A.17.2 and ANSI A.17.3 Periodic (Full-Load) Inspection: Full-load inspections will be accomplished in each of the elevators. The Periodic Full Load Inspection will include the performance of a routine inspection. Inspections will comply with elevator manufacturers' inspection criteria and applicable requirements of ANSI A17.1, ANSI A.17.2 and ANSI A.17.3. Repairs: For repairs necessary due to equipment malfunction or failure, the onsite Point of Contact will initiate a 1 day onsite Emergency Service Call. The Emergency Service Call shall include all labor, travel, and necessary per diem to accomplish the repairs. The Contractor shall be responsible for all costs associated with accomplishing repairs and replacements, including equipment and supplies for all equipment and systems specified or recommended by the system manufacturer. The contractor shall include the associated costs for the supplies and equipment in the Elevator PM, Repair, and Inspection portion of the bid schedule. A call will be generated that will include a statement of work to include what will be inspected and maintenance or repairs to be performed. Firms that are on the BPA will provide quotes to perform services for said call. Louisville district will award th…
Classification
Contracting Office
Contacts
Attachments (1)