NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # W911XK26QA021
AI Summary
• The Nicolet Crane Barge procures the •CO2 Fixed Fire Suppression System with removal of an existing, non-compliant CO2 system and furnishing and installing a new, complete marine-grade fixed fire suppression.
• No change is reported for acquisition eligibility or set-aside status; no small business program participation is restricted for this acquisition.
• The scope • removal of the existing CO2 system and Installation and procurement of Marine-grade Fire Suppression System.
NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # 1240BH26Q0050
AI Summary
• The U.S. Army Corps of Engineers requires dredging of approximately 200,000 cubic yards of sediment at McAlpine Locks and Dam on the Ohio River to maintain a navigable channel depth of 9 feet.
• This is an unrestricted, full and open competition under NAICS code 237990 (Other Heavy and Civil Engineering Construction).
• Work must maintain a 9-foot navigable channel depth near Louisville, KY; performance period spans one base year plus two or three option years.
NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # W912EF26RA007
AI Summary
• The project is located at the Lower Monumental Dam Powerhouse, Kahlotus, Washington.
• The work involves updating the HVAC control system to a modern electronic control system for optimal performance, efficiency, and indoor air quality in occupied spaces.
• The updated system must be able to provide pressurization of the control room, stairwells, and ventilation for occupant comfort during power outages or fire events.
• System requirements include efficient use of river water as a heating and cooling source, with no smoke ingress into the powerhouse.
NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # 12639526Q0210
AI Summary
• Building 6418 has an existing wet fire suppression system that requires retrofill, and a turnkey fire suppression system is needed to replace it.
• The fire panel in question is likely an obsolete old type that can connect to the new sprinkler monitoring setup; details on the specific type are not provided.
• USDA and CVPC/PEX are the primary parties involved in selecting a suitable pipe material for the project, with consideration given to Victaulic's black iron piping (Schedule 10 or Schedule 40) specifications.
• A Valid drivers license or state ID is required to attend the site visit; responses to RFI 6 may provide clarification on the preferred pipe material.
• Responses to RFIs and posts below - RFI: Could you confirm schedule requirement for this project; preference to PEX, Victaulic black iron, schedule 10, or 40?
• Responses to RFIs and posts below - Amendment 4 added a change to the response to RFI 7 posted on August 17.
• Responses to RFIs and posts below - Amendment 5 extended the closing date for this solicitation; note of new deadline: Responses due April 18, Closing by June 01
NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # W50S74-26-Q-A019
AI Summary
• The USPFO CA intends to award a single firm-fixed-price contract for construction services to provide plant, labor, transportation, materials, tools, equipment, appliances, and supervision necessary to Replace Air Handling Unit.
• The scope of work includes Replacement Rooftop AHU and associated components, with demolition as the primary requirement.
• The project magnitudes are $250,000.00 to $500,000.00, with Interested offerors needing to register in System for Award Management (SAM) within 60 days prior to bidding.
• Due to recent fraudulent activity, interested offersors must submit a notarized letter to the General Services Administration (GSA) for activation and update of their registration before they can access SAM.gov; otherwise, they will be restricted from accessing the system.
NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # W50S6M26QA014
AI Summary
• The 117th Air Refueling Wing's requirement involves conducting full inspections and repairs of existing piping systems within six selected facilities, which must be completed by June 30, with only one base year plus two option years' coverage.
• The contract is an Firm Fixed Price (FFP) acquisition for the most advantageous, Lowest Price Technically Acceptable offer to the Government.
• Written questions regarding this solicitation must be submitted via email to MSgt Jonathan Werkmeister at jonathan.werkmeister@us.af.mil by June 10, prior to the submission deadline.
NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # 36C25226B0037
AI Summary
• Pursuant to FAR 2.101, the contractor limits subcontracting for services (except construction) to 50% of government payments.
• The contractor limits subcontracting for general construction to 85% of government payments; cost of materials are excluded.
• SDVOSBs listed in SBA databases for services count towards the 50% subcontract limit; similarly situated VOSBs listed count towards the 85% subcontract limit, with cost of materials also excluded.
Note: FAR 52.2224 is not applicable since this Notice addresses subcontracting on a contract with a small business prime contractor (38 U.S.C. 8127(1)(2)).
NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # W911SG26BA008
AI Summary
• The MICC-Ft. Bliss Installation Contracting Command is seeking a single firm-fixed-price contract for the replacement of 12 HVAC Carrier rooftop units with TRANE HVAC units, located at building 1611 within Fort Bliss TX.
• The contract duration is 270 days after notice to proceed and will result in a Total Small Business set-aside under NAICS code 238220, maintaining $19,000,000.00 size standard.
• The magnitude of construction falls between $1,000,000 and $5,000,000, with no specific details given within the solicitation text regarding additional requirements or constraints.
RFPVeteran-Owned Small Business Set-Aside (specific to Department of Veterans Affairs)6
NAICS 238220 – Plumbing, Heating, and Air-Conditioning Contractors
Sol # 1240BD26Q0090
AI Summary
• The contract involves the supply and installation of an Energy Star certified single-phase heat pump system for the Mount St Helens National Volcanic Monument Ranger District Office in Amboy, WA.
• The existing HVAC system must be removed and disposed of by a license electrician off Forest Service Property; contractor shall not perform electrical work without compliance with required codes and standards.
• All equipment shall operate efficiently below 25 degrees Fahrenheit; the selected unit will have an Energy Star rating and meet or exceed NEC, NFPA, ASHRAE standards; certification will be provided by the supplier.
• The brochure detailing the included unit of their company's design features and specifications is attached.