JR & CO INC
UEI: EEV2NLW4F6C3
$50.5M
Obligations · USAspending
Actions Sep '17 – Jun '26
63
Contract awards · USAspending
—
SAM.gov award notices · 12 mo
Jun '27
Period of performance through
Top agencies
By obligations · USAspending, all years
- Department of Defense$35.6M · 62 awards
- Department of Justice$14.9M · 1 awards
Top NAICS
By obligations · USAspending, all years
- 238160 Roofing Contractors$50.5M
Recent awards
Latest contract actions by start date · USAspending
| Award | Agency | Start | Amount |
|---|---|---|---|
| W91QF426FA131 | Department of the Army | 06/10/2026 | $10K |
| W91QF426FA114 | Department of the Army | 06/09/2026 | $56K |
| W91QF426FA069 | Department of the Army | 04/07/2026 | $1.3M |
| W91QF426FA041 | Department of the Army | 03/17/2026 | $178K |
| W91QF426FA038 | Department of the Army | 03/03/2026 | $62K |
| W91QF426FA039 | Department of the Army | 02/05/2026 | $209K |
| W91QF426FA040 | Department of the Army | 02/05/2026 | $49K |
| W91QF425FA198 | Department of the Army | 09/30/2025 | $168K |
| W91QF425FA190 | Department of the Army | 09/17/2025 | $1.6M |
| W91QF425FA129 | Department of the Army | 07/10/2025 | $244K |
Expiring contracts
Period of performance ending in the next 18 months · USAspending
- 15BFA024C00000019 · Department of Justice$14.9M · ends 06/27/2027
- W91QF426FA114 · Department of Defense$56K · ends 12/05/2026
- W91QF426FA131 · Department of Defense$10K · ends 12/05/2026
Subcontracts received
Subcontracts reported by primes (FFATA) · first tier only, self-reported, may be incomplete
$5.1M
Received · FY2025–FY2027
$5.1M
Received · all years
2
Subawards
2
Primes
Top primes
| Prime contractor | Total |
|---|---|
| STAMPEDE VENTURES, INC. | $3.9M |
| WESTON SOLUTIONS INC | $1.2M |
Most recent
- $3.9MSCOPE OF WORK: 2 PLY SBS MODIFIED BITUMEN MODIFIED BITUMEN ROOFING SYSTEM 1. SET-UP STAGING AREA FOR ROOFING AS AGREED UPON SUBCONTRACTOR AND CONTRACTOR. 2. PROVIDE ALL NECESSARY PROTECTION NEEDED TO GUARD STRUCTURES FROM THE EXECUTION OF OUR WORK. 3. SET UP ALL REQUIRED SAFETY AS REQUIRED BY OSHA. 4. REMOVE AND DISPOSE OF EXISTING ROOFING SYSTEM DOWN TO STEEL DECKING AS REQUIRED TO ALLOW THE APPLICATION OF THE PROPOSED ROOFING SYSTEM. 5. FURNISH AND INSTALL VAPOR BARRIER DIRECTLY TO THE METAL DECKING. 6. FURNISH AND INSTALL TWO LAYERS OF 2.6" (R-30) ISO INSULATION MECHANICALLY FASTENED TO DECKING PER MANUFACTURER'S SPECIFICATIONS OVER ENTIRE ROOF AREA. 7. FURNISH AND INSTALL TAPERED CRICKETS AS SHOWN ON AS BUILTS. 8. FURNISH AND INSTALL ONE LAYER OF ½” COVERBOARD, ADHERED TO THE INSULATION ACCORDING TO UPLIFT REQUIREMENTS. 9. FURNISH AND INSTALL 1 LAYERS OF SBS BASE SHEET OVER ENTIRE ROOF AREA. 10. FURNISH AND INSTALL 1 LAYER OF SBS FR WHITE CAP SHEET ACCORDING TO MANUFACTURES WRITTEN INSTRUCTIONS 11. WALLS SHALL BE FLASHED WITH 1 PLY OF SBS BASE SHEET AND 1 PLY OF SBS CAP SHEET. 12. FURNISH AND INSTALL NEW SBS FLASHINGS FOR PENETRATION’S. 13. FURNISH AND INSTALL 22 GA METAL COPING CAP AT ALL PARAPET WALLS. 14. FURNISH AND INSTALL NEW ROOF HATCH. 15. FURNISH AND INSTALL LPS SYSTEM. BY SUBCONTRACTOR. 16. FURNISH AND INSTALL NEW SKYLIGHTS AS SPECIFIED IN THE SOW. 17. FURNISH AND INSTALL NEW WALK PAD AS SHOWN ON THE AS BUILTS. 18. PROVIDE DAILY CLEANUP OF WORK AREA.
- $1.2MROOFING REPAIRS