FedOps logoFedOps

M2 ELECTRIC LLC

UEI: EAKHLUBBKU27
Browse awards
$10.7M
Obligations · USAspending
Actions Mar '14 – Apr '25
46
Contract awards · USAspending
—
SAM.gov award notices · 12 mo

Top agencies

By obligations · USAspending, all years

Top NAICS

By obligations · USAspending, all years

  • 562910 Remediation Services$4.1M
  • 238210 Electrical Contractors and Other Wiring Installation Contractors$2.6M
  • 236220 Commercial and Institutional Building Construction$2.1M
  • 238990 All Other Specialty Trade Contractors$1.0M
  • 541620 Environmental Consulting Services$847K

Recent awards

Latest contract actions by start date · USAspending

AwardAgencyStartAmount
W91CRB25F0173Department of the Army04/07/2025$145K
W91CRB24F0148Department of the Army04/04/2024$84K
W91CRB24F0140Department of the Army04/01/2024$84K
W91CRB22F0229Department of the Army04/19/2022$43K
12639522C0024Animal and Plant Health Inspection Service01/28/2022$959K
W91CRB22F0006Department of the Army10/13/2021$26K
W91CRB21F0510Department of the Army09/24/2021$90K
W91CRB21F0307Department of the Army05/19/2021$133K
W91CRB21F0275Department of the Army04/20/2021$13K
W91CRB21F0226Department of the Army03/16/2021$19K

Subcontracts received

Subcontracts reported by primes (FFATA) · first tier only, self-reported, may be incomplete

$547K
Received · FY2025–FY2027
$547K
Received · all years
2
Subawards
2
Primes

Top primes

Prime contractorTotal
CHUGACH CONSOLIDATED SOLUTIONS, LLC$346K
STAMPEDE VENTURES, INC.$201K

Most recent

  • 10/17/2025 STAMPEDE VENTURES, INC. · W15QKN25FA349 · Department of Defense (DOD)
    1. DEMO OLD LIGHTS MAIN ENTRANCE. INSTALL (4) NEW WRAP AROUND BATTERY BACKUP LED FIXTURES. CONTROL OF CEILING MOTION DETECTOR 2. .DEMO OLD LIGHTS SECONDARY ENTRANCE. INSTALL (4) NEW 4' WRAP AROUND BATTERY BACKUP LED FIXTURES. CONTROL OF CEILING MOTION DETECTOR. 3. SOUTH END COMMS ROOM. RELOCATE EXISTING LIGHT. INSTALL (1) 4 WRAP LED BATTERY BACKUP FIXTURE. INSTALL WALL MOUNTED MOTION SWITCH. 4. CONNECT 3- TON MINI SPLIT. OUTSIDE UNIT APPROX.250' AWAY. SUPPLY DISCONNECTS AT BOTH ENDS. INSTALL OUTLET FOR CONDENSATE PUMP. 5. FURNISH AND INSTALL NEW 100-AMP 3 PHASE/ BOLT ON/MAIN LUG PANEL IN SOUTH END COMMS ROOM. FEED FROM HALLWAY PANEL APPROX. 100' AWAY. FURNISH BREAKER IN EXISTING PANEL. 6. RELOCATE (4) EXISTING LIGHT FIXTURES IN NORTH END COMMS ROOM. 7. INSTALL (4) NEW 4' WRAP LED FIXTURES WITH BATTERY BACKUP IN NORTH END COMMS ROOM. INSTALL WALL MOTION SENSOR. 8. CONNECT 3-TON MINI SPLIT. FEED CONDENSER. INSTALL DISCONNECT TO EACH PART AND INSTALL BREAKER IN EXISTING PANEL. INSTALL OUTLET FOR CONDENSATE PUMP. 9. INSTALL NEW 20-AMP CIRCUIT FROM NEW PANEL FOR CAMERA SYSTEM. 10. INSTALL (1) 20-AMP QUAD FOR MONITOR AT DESK. APPROX 100' AWAY FROM PANEL. 11. INSTALL (L) 20-ARNP CIRCUIT FOR SECOND MONITOR LOCATION, APPROX 100' FROM PANEL. 12. REMOVE AND REINSTALL (15) LIGHTS AFTER WORK IS COMPLETE. 13. INSTALL BOX EXTENSION RINGS WHERE DOUBLE SHEETROCK IS BEING INSTALLED APPROX. (18). 14. REMOVE AND RE-FEED (3) BASE FEEDS WHEN WORK IS COMPLETE. 15. INSTALL (3) 30-AMP L6-30 2POLE 3 WIE LOCKING RECEPTACLES. 16. INSTALL 1EA SMOKE IN EACH COMM ROOM. 17. DISASSEMBLE (7) WORKSTATIONS AND DISPOSE IN DUMPSTER. 18. DISASSEMBLE AND RECONFIGURE (2) WORKSTATIONS FOR NEW RECEPTION AREA. 19. DISASSEMBLE (18) WORKSTATIONS AND STORE THEM IN TRAILER. REINSTALL AFTER WORK IS FINISHED. 20. EMPTY ALL CONTENTS OF CONFERENCE ROOM. (1) TABLE, (12) CHAIRS, (1) WHITE BOARD AND STORE IN TRAILER. REINSTALL AFTER WORK IS FINISHED. 21. REMOVE AND REINSTALL CONFERENCE ROOM LIGHTS AS REQUIRED. 22. REMOVE AND REINSTALL ELECTRICAL BASEBOARD HEATERS. 23. REMOVE OR EXTEND EXISTING DEVICES AND REPLACE OR REINSTALL AS REQUIRED, REUSE OR PROVIDE NEW COVER PLATES. 24. RELOCATE (A) 5 DRAWER FILE CABINETS AND REPLACE THEM WHEN COMPLETE. 25. INSTALL (1100') OF 4" X 12" CABLE TRAY . 26. INSTALL (50') OF L0" WIREMOLD PN05L10-W DROPS WITH BOXES ON PRIVATE OFFICE WALLS. 27. INSTALL (150') OF 20' WIREMOLD PN05L10-W WITH BOXES FOR WORKSTATIONS. 28. INSTALL (30) POWER POLES FROM CABLE TRAYS TO WORKSTATIONS. 29. INSTALL (500') 1" RIDGED CONDUIT FROM NORTH COMM ROOM (OR NORTH SECURE AREA) TO SOUTH COMM ROOM. 30. INSTALL (600') 1.5" RIDGED CONDUIT FROM SIPER COMM ROOM TO OLD SECURE AREA. 31. RUN CONTINUOUS 6AWG COPPER FROM GROUND BOND THROUGH CABLE TRAY. 32. INSTALL (2) 4” PVX TROUGH WALL TO TRAY. 33. LIFTS FOR THIS TRADES WORK 34. BONDS 35. SUBMITTALS AND SKETCHES FOR THIS TRADES WORK. 36. AS-BUILTS AND O&MS
    $201K
  • 09/26/2025 CHUGACH CONSOLIDATED SOLUTIONS, LLC · W15QKN25FA348 · Department of Defense (DOD)
    LED LIGHTING PHASE 5C-1
    $346K