FedOps logoFedOps
Back to contract actions
PIIDW15QKN25FA349DELIVERY ORDER

STAMPEDE VENTURES, INC.

UEI: WT4BZHCLS8X7
$1,728,937.02
Awarding Agency
Sub-Agency
Department of the Army
Start Date
September 12, 2025
End Date
June 11, 2026
NAICS
PSC
Z2AA
Transactions (1)
DateMod #Obligation
Sep 10, 20250+$1,728,937
Subcontractors 4$1,243,593 total

Subcontracts reported by primes (FFATA) · first tier only, self-reported, may be incomplete

SubcontractorAmount
UEI EAKHLUBBKU27
1. demo old lights main entrance. install (4) new wrap around battery backup led fixtures. control of ceiling motion detector 2. .demo old lights secondary entrance. install (4) new 4' wrap around battery backup led fixtures. control of ceiling motion detector. 3. south end comms room. relocate existing light. install (1) 4 wrap led battery backup fixture. install wall mounted motion switch. 4. connect 3- ton mini split. outside unit approx.250' away. supply disconnects at both ends. install outlet for condensate pump. 5. furnish and install new 100-amp 3 phase/ bolt on/main lug panel in south end comms room. feed from hallway panel approx. 100' away. furnish breaker in existing panel. 6. relocate (4) existing light fixtures in north end comms room. 7. install (4) new 4' wrap led fixtures with battery backup in north end comms room. install wall motion sensor. 8. connect 3-ton mini split. feed condenser. install disconnect to each part and install breaker in existing panel. install outlet for condensate pump. 9. install new 20-amp circuit from new panel for camera system. 10. install (1) 20-amp quad for monitor at desk. approx 100' away from panel. 11. install (l) 20-arnp circuit for second monitor location, approx 100' from panel. 12. remove and reinstall (15) lights after work is complete. 13. install box extension rings where double sheetrock is being installed approx. (18). 14. remove and re-feed (3) base feeds when work is complete. 15. install (3) 30-amp l6-30 2pole 3 wie locking receptacles. 16. install 1ea smoke in each comm room. 17. disassemble (7) workstations and dispose in dumpster. 18. disassemble and reconfigure (2) workstations for new reception area. 19. disassemble (18) workstations and store them in trailer. reinstall after work is finished. 20. empty all contents of conference room. (1) table, (12) chairs, (1) white board and store in trailer. reinstall after work is finished. 21. remove and reinstall conference room lights as required. 22. remove and reinstall electrical baseboard heaters. 23. remove or extend existing devices and replace or reinstall as required, reuse or provide new cover plates. 24. relocate (a) 5 drawer file cabinets and replace them when complete. 25. install (1100') of 4" x 12" cable tray . 26. install (50') of l0" wiremold pn05l10-w drops with boxes on private office walls. 27. install (150') of 20' wiremold pn05l10-w with boxes for workstations. 28. install (30) power poles from cable trays to workstations. 29. install (500') 1" ridged conduit from north comm room (or north secure area) to south comm room. 30. install (600') 1.5" ridged conduit from siper comm room to old secure area. 31. run continuous 6awg copper from ground bond through cable tray. 32. install (2) 4” pvx trough wall to tray. 33. lifts for this trades work 34. bonds 35. submittals and sketches for this trades work. 36. as-builts and o&ms
$200,956
UEI M7P8FV9PVV73
1. complete intrusion detection system (ids) as per section 2.1.14.1.1. and security 2000 proposal q3890r3 july 21, 2025, ids installation to equal 100 percent coverage. 2. all electrical requirements for a complete ids system shall be part of this trades contract. 3. bonds 4. testing and certification reports 5. owner training 6. as-builts and o&ms
$225,681
UEI PNZYTRLNYAJ2
1. main entrance vestibule a. protect flooring b. demo existing drop ceiling (lights and exit sign removed by others) c. install rc-1 channel on existing sheetrock inside vestibule (3-walls) d. install 5/8 quite rock on 3 walls e. install armstrong suspended ceiling system f. install 2 layers of 5/8 quite rock on ceiling g. install roxul 60 acoustical insulation on ceiling h. demo existing interior door and frame modify open to fix new door i. supply (1) stc 55 metal door and buck with closer (doors are not prepped for hardware) j. labor to install door k. patch and prep existing walls (1) inside vestibule l. paint walls and ceiling 1 coat primer and 2 coats finish paint m. paint new metal doors and buck n. mount (3) precision locker supper 30 cell phone locker o. (90) orange soft spring wrist band key chain p. install (1) laptop locker 14 doors 2. secondary entrance vestibule a. protect flooring b. demo existing drop ceiling (lights and exit sign disconnected by others) c. install rc-1 channel on existing sheetrock inside vestibule (3-walls) d. install 5/8 quite rock on 3 walls e. install armstrong suspended ceiling system f. install 2 layers of 5/8 quite rock on ceiling g. install roxul 60 acoustical insulation on ceiling h. demo existing interior door and frame modify open to fix new door i. supply (1) stc 55 double metal door and 6070 buck with closer (doors are not prepped for hardware) j. supply ives sb360 12" slide bolt on fixed door top and bottom k. labor to install door l. demo existing exterior double door and frame m. supply new double doors and frame complete with metal transom to fit in existing opening n. both doors active with vertical rod exit device o. labor to install door p. patch and prep existing walls (1) inside vestibule q. paint walls and ceiling 1 coat primer and 2 coats finish paint r. caulk / paint new double metal doors and buck s. install (1) laptop locker 14 doors t. (14) orange soft spring wrist band key chain 3. door modification south end exit only a. demo existing door and frame b. supply (1) stc 55 metal door and buck with closer (material) to fit existing opening c. supply lockmaster lkm10k type ix push pull handle exit only d. labor to install door and hardware e. repair threshold f. caulk / paint door and buck 4. interior secondary door #1 a. demo existing interior door and frame modify open to fix new door b. supply (1) stc 55 metal door and buck with closer (doors are not prepped for hardware) c. labor to install door d. mount (1) precision locker supper 30 cell phone locker e. (30) orange soft spring wrist band key chain f. caulk / paint door and buck 5. interior secondary door #2 a. demo existing interior door and frame modify open to fix new door b. supply (1) stc 55 metal door and buck with closer (doors are not prepped for hardware) c. labor to install door d. mount (1) precision locker supper 30 cell phone locker e. (30) orange soft spring wrist band key chain f. caulk / paint door and buck 6. interior demising wall a. protect flooring hang plastic for dust control b. remove insulation laying on top of existing ceiling tile (save) c. demo ceiling tile and grid 5' off both sides of demising wall d. lights / exit signs / smoke detectors and pull stations removed by others e. frame 3-5/8" metal studs on top of existing wall to underside of roof f. install rockwool safe'n sound r-15 3" thick g. install 1 layer of 5/8 quite rock on non-open side and 2 layers on open storage side h. install 1 layer of 5/8 quite rock over existing wall 10' high open storage side i. seal all penetrations j. remove existing wood door in conference room (save) k. demo entire ceiling tile and grid in conference room l. note: lights / exit signs / smoke detectors / tvs / hvac and pull stations removed by others m. install new metal door buck to fix new wall width n. install 1 layer of 5/8 quite rock over existing wall 10' high on 2 remaining conferenc
$377,050
UEI SFREN5SBGGL8
1. kaba x-10 lkm locksets for main south entry vestibule, secondary entry vestibule, interior secondary entry doors #1 and #2. note: all doors shall have exposed, stainless flexible armored door cord. 2. south comms rm-un-classified cabinet (existing) a. 1ea apc xfmr, step-down 208vac to 120vac b. 1ea eaton 9px-5k 5000va ups c. 2ea eaton 9px-ebm-180rt extended batteries 3. classified networks a. 3ea panduit cn1 equipment cabinets 90”h x 30”d x 24” w, perforated front door, fan kit and casters. b. 2ea general dynamics mc-106b taclane shelf kit c. 4ea tripp lite sm3000rmxl2taa 3000va ups d. 10ea cisco c9200l-48p-4g-e network switch with dual power supplies. e. 8ea network stacking cables f. 10ea panduit dpa48688-tgy, angled 48 port patch panels. g. 10ea cisco dna essential software licenses. 4. sipr cable networking a. 200 cat6 red cables, with rj45 snaps - cubicles typically 1 snap per desk. b. 30-spaces; 15 cables at “south end of space” , 15 cables “north end of this south space” sipr cabling shall be installed exposed, along top edge of cubicle walls, and adjacent walls, in plastic inspectable raceway. c. provide fluke cable test & certification results. d. 200- 3ft and 200- 7ft red cat6 patch cords 5. cac access control system; provide & install a new independent head-end controller in the new south comms room. migrate over the two existing cac doors front vestibule, rear vestibule on to the new controller dedicated for the south open storage wing. provide an enrollment reader station in the south comms room, with engineered, option features, to “merge these new separate north & south cac systems onto a single unified together: a. 1ea life-safety power cabinet fpo150-c8p-e4m b. 1ea mp1502 ethernet controller c. 1ea mr52-s3b expansion board d. 3ea hirsch 200 bit cac card readers e. 1ea enrollment reader desk stand f. 1ea global folding wall shelf for laptop g. 2ea 12vdc 12ah batteries to provide extended service h. 1ea laptop i7 cpu, window 11 pro, no blue tooth or wi-fi i. 1ea rs2 access-it software ver.11xx with sl-8, and 2nd concurrent user license j. 2ea trendnet network switches, with sfp ports k. 2ea fiber multi-mode , media converters l. 1ea fiber multi-mode,6 strand cable, run from north to south m. labor to install cabling and readers to x10 locks for 2 new interior doors. n. labor to re-install readers to new x10 locks on front and rear vestibule doors o. re-use readers, cabling, and mercury boards on front and rear vestibule doors 6. aiphone ax series, super expandable/configurable video intercom a. 1ea aiphone central controller ax-248c b. 1ea door station w/camera ax-dv c. 2ea desk monitors ax-8mv d. power supply 24v 7. cctv camera system-all cctv equipment, shall be housed in a ups cabinet a. 1ea costar dr-8364d , 64 channel with nvr with 48tb of hdd b. 1ea tripplite rack console w/keyboard & 19” monitor #b040-008-19 c. 1ea tripplite #sm3000rmxl2utaa 3000va ups d. 6ea costar av32576sir outdoor omni-lx cameras w/wall brackets e. 6ea costar av05cid-200 outdoor dome cameras, with brackets. note: 5ea indoor cameras were changed to outside style/model. f. 12ea cameras with shielded cat6 cabling g. 12ea cameras with ids tamper switches h. 12ea cameras with surge protection i. 12ea ditek dtk-110rjc6apoe j. 1ea ditek dtk-rm12poe rack mount k. 12ea vivotek splice box for mounting surge suppressor at-cab-001 l. 12ea port patch panel, shielded cat6a rj45’s m. 2ea trendnet network switches , high current poe++ n. 30ea patch cords, cat6a shielded, 3ft o. camera conduit 8. cctv monitoring a. 2ea philips commercial 50” 4k, taa compliant monitors #50bdl4511d-27 b. 2ea wall monitor brackets c. 2ea hp pro mini 400 g9, i5 cpu, 16gig ram with uhd graphics, 1 per desk. d. 2ea trendnet network switches, with sfp ports e. 2ea fiber multi-mode , media converters f. 1ea fiber multi-mode,6 strand cable, run from north to south, conduit by others 9. p&p bond 10. testing and certi
$439,906