AI Summary
Description
This is a combined synopsis/solicitation for commercial services prepared in accordance with the format in FAR 12.603, as supplemented by the current Federal Acquisition Circular (FAC 2026 01) and the Department of Veterans Affairs Acquisition Regulation (VAAR). This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued. This acquisition is 100% set aside for Small Business concerns in accordance with FAR 19.502-2 Total small business set-asides and FAR 52.219 6, Notice of Total Small Business Set Aside. Offerors must qualify as Small Business concerns under the applicable NAICS code at the time of quote submission and at the time of award. The associated North American Industrial Classification System (NAICS) code for this procurement is 238210, with a small business size standard of $19.0 million. The FSC/PSC is J061. The Department of Veteran Affairs (VA) Central Western Massachusetts Medical Center located at 421 North Main St. in Leeds, MA 01053 is seeking to purchase services for electrical repairs as outlined in the Performance Work Statement: 04/08/2026 PERFORMANCE WORK STATEMENT VA Medical Center Leeds, MA B65 Switch 1 Repair Electrical Repair Service, VACWM, Leeds, MA GENERAL: This is a non-personnel services contract to provide electrical repairs and service. The Government shall not exercise any supervision or control over the contract service providers performing the services herein. Such contract service providers shall be accountable solely to the Contractor who, in turn is responsible to the Government. Description of Services/Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, lockout/ tagout, supervision, and other items and non-personal services necessary to perform electrical repairs and service as defined in this Performance Work Statement (PWS) except for those items specified as government furnished property and services. All shutdowns and deenergizing of equipment shall be the contractor s responsibility. The contractor shall meet the standards in this contract. The contractor shall show a minimum of 5 years of successfully completed experience in fixing and repairing medium voltage equipment, testing medium voltage equipment, and medium voltage LOTO. Installing new medium voltage equipment will not be considered as repair experience. Background: The Leeds campus has experienced a failed medium voltage electrical switch. This requires repair under the NFPA 70B and VA 1028 directive to have a safe and maintained electrical system. Objectives: Switch 1 requires internal insulators to be replaced and tested. Switch 1 is a park switch model number PM255-2-2-2-LF. Scope: After award, but prior to the start of any field work, the contractor shall contact the Project Engineer/Manager (i.e. COR) to review proposed methods and plans for completion of work and to review infection contro…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (3)