Description
Vascular Ultrasound System - Domestic End Product SCOPE OF WORK /PWS 1.0 Introduction This Statement of Work (SOW) defines the requirements of the Oklahoma City – OR & SICU Renovation in establishing a fixed-priced order for a vascular ultrasound. 1.1 Background Oklahoma City – OR & SICU Renovation requires vascular ultrasounds to outfit the new facility (Quantity 1). 1.2 Scope The scope of this purchase order is to provide Oklahoma City – OR & SICU Renovation with brand name or equal items for delivery to the Oklahoma City – OR & SICU Renovation location. Contractors shall furnish all requirements. Estimated delivery dates are August 3rd, 2026 – August 17th, 2026. Specific installation dates will be defined upon award. The delivery schedule is based upon the current construction schedule, which is subject to change. The vendor shall not increase prices for a change in delivery date due to construction delays. The awardees' actual delivery dates will be confirmed by VA upon award. 2.0 General Requirement All equipment to be supplied under the specifications shall be the newest and the most current model of a standard product of a manufacturer of record. A manufacturer of record is defined as a company whose main occupation is the manufacture for sale of items of equipment and which: a. Maintains a factory production line. b. Maintains a stock of replacement parts for the item. c. Maintains engineering drawings, specifications, operating manuals and maintenance manuals. d. Has published and distributed descriptive literature and equipment specifications on the equipment. Any equipment or service as applicable must be in compliance with the Memorandum dated March 6th, 2025, Subject: Electronic Health Record Modernization Standardization (VIEWS 12862405). Upon award: Activations PM will contact contractor in regard to specific delivery and installation dates to coordinate with other services. Specifications: X2107 - Scanner, Ultrasound, Vascular The system shall be a non-invasive vascular diagnostic system designed for arterial and venous assessment using Doppler ultrasound technology. The system shall provide physiologic testing capabilities for peripheral vascular evaluation including segmental pressures, ankle-brachial index (ABI), toe pressures, and Doppler waveform analysis. Doppler System Continuous wave (CW) Doppler system. Operating frequencies: minimum 8 MHz probe (with capability to support additional probe frequencies such as 5 MHz or 10 MHz). High-sensitivity Doppler receiver capable of detecting low-flow signals. Audio output with adjustable volume control. Visual waveform display (analog or digital) with real-time spectral or analog waveform representation. Signal-to-noise ratio sufficient for peripheral arterial and venous assessment. Pressure Measurement System Integrated non-invasive blood pressure module. Automatic cuff inflation and controlled deflation. Pressure range suitable for peripheral vascular testing (minimum 0-300…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)