AI Summary
Description
THIS IS A PRESOLICITATION NOTICE The Department of Veterans Affairs, Network Contracting Office 9, located at 1639 Medical Center Parkway, Suite 204, Murfreesboro, TN, 37129, anticipates issuing a solicitation Request for Quotation (RFQ) on or about 06/23/2026 for two EQUAL or better semi-instantaneous vertical CEMLINE hot water heaters on behalf of the James H. Quillen VA Medical Center, located in Mt. Home, Tennessee. Situation: The two hot water heaters in building 005 MTN Home VAMC have failed due to being at their end-of-life cycle and require replacement. These are specialty semi-instantaneous vertical hot water heaters fabricated in accordance with ASME codes and stamped for 150 psi working pressure. The packaged water heater will be constructed with a Stainless-steel tank and Stainless-steel threaded openings. Heater will be mounted on a steel support skid and will have lifting lugs. Heater will be insulated with foam insulation and protected by an enameled metal jacket, 20-gauge thickness. These water heaters are specialty units that must function within the existing mechanical room space. I 5 _, OU.... ,,_"A""""""' T _, NOTE: THE REPLACEMENT HEATERS MUST MEET THE PRECISE MEASUREMENTS TO FUNCTION WITHIN THE EXISTING SPACE. Standard Specifications must meet or exceed: Heater will be factory assembled and piped including: Incoming steam strainer Electric operated temperature regulators Main and auxiliary float and thermostatic steam traps Double wall, copper tubes, copper lined tank side/steel head side tube sheet and cast-iron steam chamber. Intra tank circulator. ASME pressure- temperature relief valve. Water pressure gauge and steam pressure gauge. Solid State Control module that includes the following functions with individual pilot lights: On-off switch, remote start-stop, alarm horn with alarm silence button, power on, primary high limit, and secondary high limit. Module will have built in PIO Control signal with LED display of set point and operating temperature read out and contacts for BACnet and Computrol Compatible (Front -End capability). Double solenoid safety system. Vacuum Breaker. Heater shall be rated to heat 27 G.P.M. of water from 40 F. to 140 F. and control the outlet within 5 degrees of the selected temperature when supplied with 15 PSIG of saturated steam to the control valve. Heater will be mounted vertically. The Department of Veterans Affairs, Network Contracting Office 9, is seeking to purchase the following: CLIN Model Number DESCRIPTION QTY 0001 V8SEH830DW CEMLINE WATER HEATER 2 SET-ASIDE: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) NAICS Code: 333415 Air Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing SBA SIZE STANDARD: 1,250 Employees PSC: 4520 Space and Water Heating Equipment DESCRIPTION: This requirement is for the James H. Quillen Veterans Affairs Medical Center located at the address listed below: James H. Quillen VA Medical C…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)