Description
Sources Sought Notice This is not a request for formal proposals or quotes, it does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified businesses interested and capable of providing the required services. Documentation of technical expertise must be presented in sufficient detail for the government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone and email (e) UEI number (f) Cage Code (g) Type of small business, e.g., Services Disabled Veteran Owned Small Business, Veteran-Owned Small Business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, Small Business, or Large Business; and (h) capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. Please indicate whether you hold a GSA Federal-Supply-Schedule or Indefinite Delivery/Indefinitely Quantity (IDIQ) contract that covers this type of request. If so, please provide the Schedule contract number. This Sources Sought is for the Robert J. Dole VAMC who has a requirement for ChemDAQ (Steri-Trac St2). This includes delivery, labor, installation and training to be completed by the vendor on-site. BRAND NAME OR EQUAL for all line-items listed below. Brand-Name Product Information: Manufacturer: ChemDAQ Description/ Part Number Qty 12 Mo Extended Warranty % of HW/SW for Steri-Trac® 2 Equipment 1 Steri-Trac® 2 One Year SXP® for Steri-Trac® 2 Monitor for Hydrogen Peroxide 1 Steri-Trac® 2 One Year SXP® per Steri-Trac® 2 Monitor for Peracetic Acid 1 Steri-Trac® 2 Remote Display (Limit 3 per Monitor) 2 System Commissioning with In-Service Training for Steri-Trac® 2 Equipment 1 Salient Characteristics Advanced Gas Detection Technology Real-Time Continuous Monitoring User-Friendly Interface High Sensitivity and Precision Sensors Visual and Audible Alarms Data Logging and Reporting Capabilities Must be able to monitor Peracetic acid Must be able to monitor Hydrogen peroxide Technical Characteristics Parameter Hydrogen Peroxide (H2O2) Peracetic Acid (PAA) Sensor Principle Electrochemical Electrochemical Range 0 20 ppm 0-3 ppm Accuracy2 10% 5% Calibration Interval 4 Months 4 Months Resolution 0.1 ppm 0.01ppm Temperature Range 0 to +50°C - 20 to +50°C Response Time (T90 (s)) 0ºC 15 to 95 % noncondensing. Dew Point> 0ºC Must have an Authorized Distributor Letter issued from the manufacturer if not the manufacturer The NAICS Code is 334519 with a Small Business size standard of 600 Employees. SDVOSB/VOSB vendors must be registered in the SBA VetCert…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)