AI Summary
Description
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 333310 Commercial and Service Industry Machinery Manufacturing (size standard of 900 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The purpose of this procurement is to acquire [2] high speed floor burnishers that meet the performance, durability, and safety specifications required for daily hospital operations for the Tucson VAMC Engineering Department while meeting specifics list below. The contractor shall provide new, fully assembled floor burnishers, including all accessories, manuals, warranties, and deliveries to the designated VA facility. The contractor should also provide on-site training for EMS staff after delivery: Salient Characteristics (Brand-Name or Equal Requirements) Brand Name Item: Tennant B10 Battery Rider Burnisher, B10-690 Figure 1 Proposed floor burnishers must meet or exceed the following minimum specifications: Power Source: Battery-operated, onboard charger included Pad Size: 20-inch burnishing pad Burnishing Speed: Minimum 1500 2000 RPM Sound Level: 68 dB(A) for hospital appropriate quiet operation Traction System: Transaxle drive or equivalent self propelled assist Dust Control: Active or passive dust-collection system Battery Type: Minimum 200 AH wet or sealed maintenance free batteries Frame: Heavy-duty steel or reinforced composite construction Safety Features: Emergency stop Operator presence control Non marking wheels Accessories Required: Burnishing pads (quantity: [X]) Replacement dust bags/filters (quantity: [X]) Warranty: Minimum 1 year warranty on parts and labor; 3 year warranty on motor preferred Deliverables The contractor shall deliver: [2] Floor Burnishers, new and fully operational All required accessories, as listed in Section 4 Owner s manuals and safety…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (2)