AI Summary
Description
Request for Quote (RFQ): Power Plant and Monitoring Systems Maintenance (i) This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part RFO Part 12. This announcement constitutes the solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number F1S3AC6085AQ01 is issued as a Request for Quotation (RFQ) for Power Plant and Monitoring Systems Maintenance. This acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. (ii) A list of line-item number(s) and items, quantities, and units of measure. • CLIN 0001: o BACS and Maintenance on (10) BACS Systems of (24-72) battery strings. including one UPS system (Eaton 9PXM) • QTY: o 2 PMI's Each/year • UNIT OF MEASURE: o Each (iii) Description of requirements for the items to be acquired: • Perform full system calibration check and firmware update • Inspect all battery posts for signs of leakage • Complete full impedance and conductance testing • Download, compile and review all available historical data for trending and • Complete any alarm testing requested • Re-adhere all modules where required • Verify all BACS Viewer installation and retrieved data • Verify time server function operational • Check all physical battery and battery monitoring connections • Verify E-Mail and remote alarms all indicating (where installed) • BAC2S Module cleaning by qualified personnel. • Prepare report for any failed or degraded batteries found during inspection or stored history • GENEREX authorized/certified technicians (iv) Date(s) and place(s) of delivery and acceptance and f.o.b. point: Dates: • Base Year: 09 August 2026 - 08 August 2027 • Option Year 1: 09 August 2027 - 08 August 2028 • Option Year 2: 09 August 2028 - 08 August 2029 • Option Year 3: 09 August 2029 - 08 August 2030 • Option Year 4: 09 August 2030 - 08 August 2031 Places of Delivery: Edwards AFB, CA • Bldg. 2600, Battery Room, GNB Absolyte, 100G-63, 2 Strings, 144 batteries • Bldg. 2600, Room 114, GNB Absolyte, 50G-07, 2 Strings, 48 batteries • Bldg. 2600, Room 114, (UPS Units) Eaton 9PXM, 2 Strings, 10 UPS units • Bldg. 2600, Room 112, C & D Technologies, MS Endur II, 3 Strings, 72 batteries • Bldg. 4231 (SN1), GNB Absolyte, 100G-23, 1 String, 24 batteries • Bldg. P300 (SN2), GNB Absolyte, 100G-23, 1 String, 24 batteries • Bldg. 5557 (SN3), GNB Absolyte, 100G-25, 1 String, 24 batteries • Bldg. 8359 (SN4), GNB Absolyte, 100G-19, 2 Strings, 48 batteries • Bldg. 1449, C & D Technologies, MS Endur II, 2 Strings, 32 batteries • Bldg. 3812, C & D Technologies, MS Endur II, 2 Strings, 32 batteries (v) A list of solicitation provisions that apply to the acquisition are as follows: 252.203-700 - Representation Relating to Compensation of Former DoD Officials. 252.204-7008 - Compliance with …
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)