Page 1 of 14 Page 12 of 12 Page 1 of 14 STATEMENT OF WORK CONTRACT TITLE: Fire Sprinkler repairs PLACE OF PERFORMANCES: VA San Diego Healthcare System 3350 La Jolla Village Dr. San Diego, CA 92161 PERIOD OF PERFORMANCE: 07/01/2026-06/30/2027 CONTRACT TYPE: Firm Fixed Price BACKGROUND: Fire sprinkler deficiencies from 2025 annual inspection and testing. GENERAL REQUIREMENTS: Per applicable VA San Diego requirements/standards, the contractor will: BLDG 1 WETPIPE REQUIRED REPAIRS: **** 6TH FLOOR **** NORTH: The following areas were found to have 50yr old sprinklers: 6231 (2), 6232 (2), 6233A (2), 6242 (2), 6239 (2), 6240, 6233 (2), 6243 (2), 6254 (6), 6245 (2), 6246 (4), 6246A (2), 6230 (4), 6252B (2), 6252C (1), 6252E (4), 6247 (2), 6249 (2), 6250 (1), 6251 (1), 6254 (6), 6254A (2), 6256 (2), 6257 (2), 6264 (1), 6254B (2), 6263 (2), 6267 (6), 6268 (1), 6269 (2), 6259 (2),6263A (1), 6224 (1), 6225 (1), 6219 (2), 6218 (2), 6217 (4), 6215 (1), 6268 (2). Replace (88) 165° STD ½ Chrome SSP 401chrome trim. WEST: The following areas were found to have 50yr old sprinklers: 6097 (1), 6024 (1), 6035 (4), 6025 (2), 6032 (2), 6030(4), 6070 (1), 6029 (2), 6083 (2), 6082 (2), 6050 (1), 6045 (2), 6080 (1), 6081 (14), 6062 (3), 6048 (2), 6051 (2), 6049 (2), 6052(5), 6055 (3), 6058 (2), 6061 (2), 6056A (2), 6069 (2), 6074 (2), 6086 (2), 6087 (2), 6088 (4), 6095 (2), 6096 (2), 6091 (1), 6091A(1). Replace (82) 165° STD ½ chrome SSP 401 chrome trim. SOUTH: The following areas were found to have 50yr old sprinklers: 6105 (3), 6107 (4), 6110 (4) 6118 (2), 6112 (1). Replace(14) 165° STD ½ chrome SSP 401 chrome trim. EAST: The following areas were found to have 50yr old sprinklers: 6149 (1), 6150 (4), 6153 (2), 6160 (1), 6163 (2), 6164 (4),6169 (2), 6170 (2), 6171 (2), 6172 (2), 6176 (2), 6174C (3), 6174G (4), 6174F (4), 6184 (2), 6189A (3), 6189C (2), 6187 (1), 6190(1), 6191 (2), 6192 (2), 6197 (1), 6198 (2) , 6200 (3), 6202 (2), 6203 (2), 6204 (2), 6205 (2), 6207 (2). Replace (66) 165° STD ½ chrome SSP 401 chrome trim. CORE: Housekeeping closet 6010 replace (1) corroded 155° QR ½ chrome SSP SRC trim. NORTH: 6254B replace (2) 20yr old 155° QR ½ chrome SSP 399 chrome trim (2001). NORTH: 6252A next to cage washer door replace (1) corroded 200° QR ½ chrome SSP 401 Chrome trim. NORTH: 6268 replace (2) 20yr old 155° QR ½ chrome SSP 401 chrome trim (2001). WEST: refrigerator 6037 replace (2) 20yr old 200° QR 1 x 12 chrome dry pendant w/ chrome trim (2002). NOTE: This will require majority stitch work. WEST: 6028 replace (2) loaded/corroded 155° QR ½ chrome SSP 401 chrome trim. WEST: 6044A in 6043 replace (1) corroded 155° QR ½ white SSP SRW. WEST: 6044 entry replace (1) corroded 155° QR ½ white SSP SRW. WEST: 6040 women s bathroom shower replace (1) corroded 155° STD ½ chrome SSP 401 chrome. WEST: refrigerator 6081E replace (1) 10yr old 200° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6070 r…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)