AI Summary
Description
This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined. Scope of Work. The procurement shall include all parts, materials, installation labor, software/licenses, resources, and training required to implement and utilize the equipment/system to their fullest capacity. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request. Specifications. 4.1 Equipment Line Item Description Quantity PA S00065 - IPV1, Airway Clearance, Dual Gas- Unit and Oxi Hose Only. NO Roll Stand (PA A50075-B), Pole Clamp (PA A50289) - Previously P/N PA K00065-US-NRS 2 PA A50075-B - Stand for IPV (A50075-B) 2 PA A50289 - IPV Stand Bracket System / Pole Clamp 2 104255 - tCOM+ Hospital USA 1 101342 - V-Sign Sensor VS-A/P/N [1/PK] 1 GCX-RS - Roll Stand GCX RS-0006-64 [1/PK] **Must order with plate** 1 tCOM-GCX-MP - tCOM+ Vesa Mounting Plate GCX FLP-0001-17 [1/PK] 1 4.2 Required Features IPV1 Airway Clearance (Brand Name or Equal): Unit dimensions must not be greater than 10 x 8 x 7 Units must come with a cart or IV pole and be mountable to this cart or IV pole Unit weight no greater than 4 pounds Operating temperature range between 65 °F to 80 °F Must support wall gas source of 47-80 psi, 3.24-5.5 bar and flow > 35 lpm Must include automatic pulse interval ratio Must be capable of non-continuous run time Must support aerosol flow of 25 lpm (0.75 - 1 ml per minute liquid consumption rate) Pulse amplitude of 0 to 50 cmH2O/hPa at 100 cycles per minute using Siemens®-style 1L test lung or equivalent Must support a pulse amplitude of 100-300 pulses per minute Mean airway pressure range must be 0-50 cmH2O Batteries: Batteries must be CR123A batteries Batteries must operate for at least 3,250 hours at 95 °F tCOM+ Respiratory Patient Monitor (Brand Name or Equal): Must meas…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)