AI Summary
Description
***Amendment 0001 - This amendment is to change the Period of Performance to 09/14/2027-09/18/2027 and to change the Place of Performance to NOAA Ship Rainier, MOC-P, 2002 SE Marine Science Drive, Newport, OR 97365. No other changes to the solicitation.** REQUISITION 140802-26-0604 This is a Combined Synopsis/Solicitation for Commercial Items prepared in accordance with the format in FAR SUBPART 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This Combined Synopsis/Solicitation #1333MK26Q0118 constitutes a Request for Quotation (RFQ) which Incorporates provisions and clauses in effect through the Federal Acquisition Circular 2026-07. The National Oceanic Atmospheric Administration (NOAA), Office of Marine & Aviation Operations (OMAO), Marine Operation Center (MOC), NOAA Ship Rainier requires the procurement of troubleshoot and repair service for their aft boiler. The solicitation is being issued as a total small business set-aside. The associated NAICS code is _336611_ with a size standard of _1,300 employees_. Quotes will be evaluated in accordance with FAR 52.212-2 Evaluation-Commercial Products and Commercial Services (Nov 2021). Responses are due by 4:00pm PDT on 08/28/2026. There will be no exceptions to the time and date on which responses are due, unless determined otherwise by the Government. Your response, technical, and pricing should be forwarded electronically to the Contracting Specialist via email no later than the date and time specified above. When responding, please include the Requisition number in the subject line. To verify receipt of your response, please contact me either by email or phone. Isaac Bright isaac.bright@noaa.gov FIRM FIXED PRICE (Service) CLIN 0001 – serviced as follows: Troubleshoot, repair and tune NOAA ship RAINIER's boilers. STATEMENT of WORK Boiler Troubleshoot and Repair – NOAA Ship Rainier 140802-26-0604 1. Hi R Temp Boilers. 1.1. Scope: 1.1.1. Troubleshoot and repair the NOAA ship RAINIER’s aft boiler. 1.1.2. Tune the boilers. 1.2. References: 1.2.1. VAPOR POWER HI R TEMP Tech Manual (ship provide) 1.3. Requirements: 1.3.1. Provide field service and materials to troubleshoot and tune the ship’s two (2) boilers: Vapor Power HI R Temp Model # MNC 5953 AHK 25 Spec # 6505501044 Serial # 23357 Model # MNC 5955 AHK 26 Spec # 6505501044 Serial # 23356 a. Troubleshoot: 1. AFT boiler – unburnt fuel in the gas chamber, boiler continues to stay lit after shut down due to unburnt fuel. b. Tune: 1. Adjust control, fuel and air settings as necessary on both FWD & AFT boilers. 2. Verify the operation of the Flame Detector Control and Program Control is operating within set points. 1.4. Period of Performance: 09/14/2026 - 09/18/026 1.5. Place of Performance: NOAA Ship Rainier MOC-P 2002 SE Marine Science Drive Newport, OR 97365 UTILIZATION OF FEDCONNECT® FOR CONTRACT A…
Classification
Contracting Office
Contacts