AI Summary
Description
Synopsis PR: FD20302700139 / SPRTA127R0130 1. Estimated issue date and estimated closing/response date: Issue: 18 November 2026 Closes: 3 December 2026 2. RFP# SPRTA127R0130 3. Service/Spare/Repair/OH: New Material Spares 4. AMC: 1/C 5. Nomenclature/Noun: STACK RING LINER AF 6. NSN: 2840012459464 7. PN: 6041T18G04 (CAGE: 85291) 8. History: SPRTA125C0005 NOV2024 B.H. AIRCRAFT COMPANY, INC (6041T18G04 CAGE: 85291) 9. Description/Function: 3.0000' FT LG X 18.0000" IN WI X 18.0000" IN HI and 5.0000 LB Weight. Material is Cobalt Alloy. Function is Afterburner of jet engine. 10. Total Line Item Quantity: L/I 0001: 861 EA. 11. Application (Engine or Aircraft): J85 12. Destination: L/I 0001 Ship to SW3211 13. Required Delivery: L/I 0001: Delivery 5 December 2028 – 5 February 2029. 14. Qualification Requirements: Do not exist. 15. Export Control Requirements: Yes 16. UID: Note to Contractor: UID requirements will apply. 17. Qualified Sources: B.H. AIRCRAFT COMPANY, INC. (Cage: 85291), GENERAL ELECTRIC COMPANY(Cage: 99207) 18. Set-aside: This acquisition will not be set aside. 19. Mandatory Language: This part requires engineering source approval by the design control activity in order to maintain the quality of the part. Existing unique design capability, engineering skills, and manufacturing knowledge by the qualified source(s) require acquisition of the part from the approved source(s). The approved source(s) retain data rights, manufacturing knowledge, or technical data that are not economically available to the Government, and the data or knowledge is essential to maintaining the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. The qualification procedures must be approved by the Government engineering activity having jurisdiction over the part in the intended application. In accordance with FAR 5.207(c) (16) (i), all responsible sources may submit a bid, proposal, or quotation which shall be considered by the agency. Foreign owned firms are advised to contact the contracting officer or program manager before submitting a proposal to determine whether there are restrictions on receiving an award. It is suggested that small business firms or others interested in subcontracting opportunities in connection with the described procurement make contract with the firms(s) listed. This acquisition involves technology that has a military or space application. The extent of foreign participation has not yet been determined. Nothing in this notice contradicts other restrictions, identified in the synopsis notice or solicitation, regarding eligible sources (e.g., if this is a small business set aside, foreign sources may not participate as potential prime contractors but could, if otherwise eligible, participate as subcontractors). Based up…
Classification
Place of Performance
Contracting Office
Contacts