AI Summary
Description
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice Page 3 of 16 DESCRIPTION Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of Page 1 of This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This is a Request for Quote (RFQ), and the solicitation number is 36C26026Q0979. The Government anticipates awarding a firm-fixed price service order from this solicitation. This solicitation is 100% set aside for Small Business. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at https://www.acquisition.gov/far-overhaul The associated North American Industrial Classification System (NAICS) code for this procurement is 334516 and the PSC is 6515. The Department of Veterans Affairs, Veterans Healthcare Administration, Regional Procurement Office West, Network Contracting Office 20, on behalf of the Portland VA Medical Center, is seeking the following. Any reference to manufacturer nomenclature/ part numbers are for reference only. This requirement is for Thyroid Uptake Systems per the Salient Characteristics listed and Statement of Work below: Pricing Table Description/Part Number* Qty Unit Price Thyroid Uptake System with 1 Well 1 EA CAP DICOM Interface 1 EA Neck Phantom for Thyroid Uptake System 1 EA On-site training and installation 1 JB Basic Technical Support 1 YR TOTAL MINIMUM SALIENT CHARACTERISTICS Thyroid Uptake Measurement System 1. General System Functionality Must be a comprehensive nuclear medicine measurement system capable of performing thyroid uptake measurements, wipe tests, bioassay measurements, and automated quality assurance functions. Must include a software-driven workflow that supports predefined protocols and customizable measurement sequences. 2. User Interface & Computer Requirements Must utilize a color touch screen user interface with a large-format display (minimum 20 inches for visibility during procedures). Must operate on the current, widely supported Windows OS platform. Must support generation of reports containing graphics, isotope spectra, and archived data, with ability to save or print reports in PDF format. 3. Detector & Measurement Specifications Thyroid Uptake Detector Must utilize a NaI(Tl) scintillation detector capable of precise uptake measurements. (Spec: 2 inch diameter NaI(Tl).) Must include a collimator meeting recognized nuclear medicine performance standards (e.g., ANSI or IAEA). Must include a physical measurement/alignment mechanism to ensure consistent detector to thyroid distance. Multichannel Analyzer (MCA) Must include an MCA with a minimum of 1024 channels. Must provide automated and manual calibration capabilities. Must support user defined and preset ROIs, live time, real time, and to…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)