AI Summary
Description
THIS REQUEST FOR INFORMATION (RFI) /Â SOURCES SOUGHT NOTICE IS ISSUEDÂ SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 33 (size standard of 1250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. VA San Diego Healthcare System needs a contract for one time service to provide replacement of batteries for the Main Server UPS (Uninterrupted Power Supply) in Bldg. 1 Room BB100-1 at VA San Diego Medical Center. The UPS are powered by 2 battery cabinets (30 per cabinet), which provide backup power during outages of normal and emergency power. This will prevent data loss, equipment damage, and ensure the continuous operation of the facility's information technology main servers. However, those batteries average lifespan is past the manufacturer's recommendation of 5 years. The battery lifespan and peak condition is essential to keeping vital equipment powered on during power surges and unexpected power shutdown. The contractor will: (1) Verify UPS is operational prior to replacing batteries. (2) Place UPS from Inverter to Maintenance Bypass. (3) Lock out/Tag out (LOTO) primary feed (Panel EDM). Verify no power at the UPS. (4) Remove and replace 60 UPS batteries with battery type UPS12-545PLP. (5) Battery terminals will be connected and tightened down in accordance with the manufacturer s recommended torque value and documented. (6) Clear all Lock out/Tag out (LOTO) and place UPS from Maintenance Bypass to Inverter mode. (7) Verify UPS is operational. Submit 1 hard copy and 1 electronic copy of Service Report. (8) Dispose of all old batteries at approved hazardous waste collection facility. Salient Characteristics for Sixty (60), UPS12-545PLP to include the following: a. Battery Manufacture: C&D Technologies b. String Voltage: 360 c. Float Voltage: 410 d. Battery Part Number: UPS12-540MR e. Batteries in a String: 30 for each …
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)