The purpose of this amendment is to answer submitted RFIs. All other terms and conditions remain unchanged. Solicitation Number: 36C24126Q0569 Project Name: Grounds Maintenance Request For Information Can the Government please provide recent stormwater system inspections characterizing accumulated debris and/or depths recorded for each of the catchments shown on the site plan? There is limited stormwater system inspections to determine accumulated debris or recorded depths for each catchment in the site plan.  Are there any known areas within the stormwater collection conveyance having a history of slowly draining? If yes, can the Government please delineate those areas on the site maps provided. The Government has no knowledge of known areas within the stormwater collection conveyance having a history of slow draining.  Can the Government please provide site utility as-built plans that show all invert elevations for the stormwater piping system?  Utility as-built plans of inverted elevations for stormwater piping systems are not available.   Are there water hydrants on site available for filling jet/vacuum trucks? If yes, what are the requirements and/or additional costs for using this source? There may be availability of the existing water hydrants to fill jet/vacuum trucks. Requirements and cost will need to be determined.  Can the Government please clarify what storm drain(s), including size and type of material, need to be replaced? Storm drains will need to be identified for size and material type on an individual basis.  Can the Government please clarify if all termination covers need to be replaced, regardless if they are in good operational condition? Not all termination covers will need replacing. Will the termination covers need to be replaced If there are visible and existing signs of defected frames? Will the frames also need to be replaced before new covers can be installed? This will be determined individually based on VA policy and requirements.  Can the Government please provide the dimensions of the covers? Dimensions can be provided on re-placement determination.  Can the Government please provide the dimensions of the catch basins? Dimensions can be provided on re-placement determination. Are there double catch basins on site? The Government is not aware of double catch basins on site currently.  Are there any pre-treatment systems that need to be inspected and cleaned, i.e., Vortechnic units, oil/water separators, etc.? None When was the stormwater and collection and conveyance system installed? Multiple phases from 1950 to present date. Since the original system was installed, how many times have the stormwater pipes been jetted clean and how many times have the catchments been vacuumed and jetted cleaned? Can the government provide any records and/or reports of these activities? Government cannot validate amount of times stormwater pipes have been jetted and/or how many times the catchments have been jette…
Classification
Place of Performance
Contracting Office
Contacts