AI Summary
Description
Project # 589A7-23-306 Renovate 5 & 5B for Mental Health The Department of Veterans Affairs, Network Contracting Office (NCO) 15, has a requirement for Renovate 5 & 5B for Mental Health, project number 589A7-23-306, located at the U.S Department of Veterans Affairs, Robert J. Dole VA Medical Center 5500 E Kellogg Dr, Wichita, KS 67218 The following narrative is intended to provide an overview of the scope of work for the proposed project. Period of Performance 210 calendar days after Notice to Proceed (NTP) Scope of Work Contractor shall perform construction and renovation of the existing space in Building 5 &/or 5B at the Robert J. Dole VA Medical Center campus. This project will prepare approximately 1,100 SF of existing space in building 5 and/or 5B for use as a same day access mental health clinic in adherence to VHA directive 1231(2) & VHA Handbook 1160.1. This project shall be executed in a manner, following the sequence defined in the design narrative, to maintain continuous operations of adjacent VA clinical functions and medical center functionality throughout construction. All construction work shall be performed in full compliance with the complete set of bidding documents, including all contract drawings, specifications, and design narratives associated with this solicitation necessary to convert the existing space into four exam rooms, a combined waiting/reception area, a relocated police office, and associated support spaces. The general contractor shall furnish all labor, supervision, materials, tools, and equipment necessary to execute the required scope of work. Construction will consist of, but is not limited to, the following: Selective demolition of existing interior partitions, ceilings, finishes, and elements required for new clinic layout. Installation of new interior finishes including flooring, wall finishes, ceilings, trim, and casework. Implementation of therapeutic design features, including calm color schemes, anchored artwork, secure hardware, and achieving a minimum STC-45 acoustic rating for exam room partitions. Installation of new wall-mounted lavatories in each exam room. Routing new domestic hot and cold water from adjacent restrooms and trenching new water lines across the corridor to existing tin-in points. Rebalancing and modifying HVAC systems; reusing the existing rooftop AHU serving the building; relocating or adding diffusers/grilles; installing ligature-resistant diffusers in exam rooms Providing new electrical receptacles, data outlets, and circuits to support clinical functions Installing LED lighting including secured, ligature-resistant fixtures in exam rooms; relocating or supplementing lighting in general spaces; adding occupancy sensors. Removal of existing sprinklers, providing temporary upright sprinkler coverage during construction, and installing new sprinklers to meet NFPA 13 standards Site preparation for installation of Government furnished equipment, including structural supports, utility…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)