Title: Sources Sought Notice for BMF Thermo Chillers BACKGROUND The National Institute of Standards and Technology (NIST) Boulder has a state-of-the-art research laboratory (the Katharine Blodgett Gebbie Building) to support the most sensitive research done at NIST. Included in this building is a Class 100 microelectronics fabrication facility, called the Boulder Micro-Fabrication Facility (BMF). The BMF has many microfabrication tools that require cooling water in order to operate. These tools are cooled using thermos-chillers. To allow for stable spare units, parts, and drop-in replacements, the BMF has standardized to SMC thermos-chillers to minimize tool down time and required inventory control. The BMF requires additional SMC thermos-chiller units in order to keep the facility operational. NIST is seeking information from sources that may be capable of providing SMC thermos-chillers that. The unit must be drop incompatible with the Government's existing SMC HRSF024-AN-20 units. This includes all hardware, software, electrical, and plumbing connections. It must also be able to be repaired with the Government's existing spare parts for a SMC HRSF024-AN-20 model thermo-chiller. NIST is seeking information from sources that may be capable of providing a solution that will achieve the specifications described below: SMC HRSF024-AN-20 Chillers: SMC HRSF024-AN-20 thermo-chiller units or equivalent, that meet the following: The unit must be drop incompatible with the Government's existing SMC HRSF024-AN-20 units. This includes all hardware, software, electrical, and plumbing connections. It must also be able to be repaired with the Government's existing spare parts for a SMC HRSF024-AN-20 model thermo-chiller. Circulating fluid: water Temperature range setting: 5 to 40 C Cooling Capacity: 2400 W Circulating water flow rate: 7 L/min Temperature Stability: +/- 0.1 C Power supply: 208 V 60 Hz single phase Air Cooled All units shall have a 1-year factory warranty. HOW TO RESPOND TO THIS NOTICE In responding to this notice, please DO NOT PROVIDE PROPRIETARY INFORMATION. Please include only the following information, readable in either Microsoft Word 365, Microsoft Excel 365, or .pdf format, in the response: Submit the response by email to the Primary Point of Contact and, if specified, to the Secondary Point of Contact listed in this notice as soon as possible, and preferably before the closing date and time of this notice. Please note that to be considered for award under any official solicitation, the entity must be registered and “active” in SAM at the time of solicitation response. Provide the complete name of your company, address, name of contact for follow-up questions, their email, their phone number and, if your company has an active registration in https://sam.gov, your company's Unique Entity ID (UEI). Identify the equipment that your company sells that can meet the objectives addressed in the BACKGROUND section of this notice. For…
Classification
Place of Performance
Contracting Office
Contacts