Stationary Nitrogen Generator System The contractor shall provide a self-contained, outdoor-rated Stationary Nitrogen Generator System meeting the following minimum specifications: Environmental: Designed for continuous outdoor operation in all standard weather conditions. Configuration: Self-contained unit including an integrated air compressor. Purity & Flow Rate: >= 99.5% dry nitrogen at a rate of 9 to 17 SCFM. Output Pressure: Boosted outlet pressure of 3,000 to 5,000 PSIG. Storage Capacity: Minimum 912 cubic feet of ready-to-use nitrogen storage at 3,000 to 5,000 PSI (provided via an indoor-installed, two-bottle storage system). Electrical: 480 VAC, 3-Phase, 60 Hz. 2. Delivery & Acceptance Delivery Schedule: 120 Calendar Days After Receipt of Award (ARO) or sooner. Government Acceptance: Final acceptance is contingent upon 100% on-site testing of all delivered materials by Government personnel.