AI Summary
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. THIS IS STRICTLY MARKET RESEARCH. Patient safety lifts The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide Patient safety lifts. All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum: (1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation. Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via email to kurt.fritz@va.gov RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement. Salient characteristics (QTY 21) Patient Safety Lifts All ceiling mounted hoists, rails, and components must comply with ISOÂ 10535:2021 xy Systems Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. Cover 5m X 10m area with trainer (QTY 1) Cover 4m X 4m area (QTY 9) Cover 4m x 3m area (QTY 2) Cover 3m x 3m area (QTY 1) Linear Tracks Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. 3m Linear Track (QTY 3) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better 4m Linear Track (QTY 4) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up 825 lbs. or better 6m Linear Track (QTY 1) Mu…
Classification
Contracting Office
Contacts
Attachments (1)