RENTAL SERVICES FOR 1,000Kw GENREATOR Background USCGC POLAR STAR is preparing to get underway while a Ship Service Diesel Generator is unavailable. To sustain required cutter capability, the United States Coast Guard requires temporary portable electrical-generation capability, including the equipment and accessories necessary to connect the generator to the cutter's Viking International shore-tie connections. The rented generator will be placed aboard the cutter and used as temporary shipboard electrical generation during the rental period. Scope . Provide rental and delivery of one portable generator package meeting the requirements below to the delivery location identified in this SOW for an anticipated rental period of approximately six months. The contractor shall also retrieve the generator package from the pier at the end of the rental period. Minimum power rating 750 kW (prime), maximum 1000 kW, 450/480 VAC, 3-phase, 3-wire power. Generator must be able to withstand 1.5 times rated current for up to 30 seconds. Minimum generator insulation class F. Electrically operated generator circuit breaker, of either insulated-case or power circuit breaker type, must be installed for protection of the generator and the connecting power cable, with electronic trip unit capable of long-, short-, and instantaneous tripping. Circuit breaker must be rated for minimum 45 kA asymmetric interrupt rating. Protection settings must be set for generator protection in accordance with American Bureau of Shipping (ABS) Marine Vessel Rules (MVR) 2025 Part 4, Chapter 8, Section 2, Paragraph 9.11 (4-8-2/9.11). Specifically: Overload protection Short-circuit protection Thermal damage protection Reverse power protection Prime mover shutdown Undervoltage protection 300' of cable rated for 115% of generator maximum current in 40 deg C ambient, minimum 90 deg C rated cable. Cable must be rated for flexible service, single conductors no larger than 4/0 for purposes of installation on the ship. Generator must be enclosed in a standard 30-foot or 40-foot shipping container. Exact specifications and dimensions must be provided in the proposal. Internal lighting, and all necessary control systems for operators to manage the system inside the container must be installed. Generator engine must be electrically started. Battery capacity must be sufficient when fully charged for at least 10 starts. Switchgear and bus bar must be braced for asymmetric short-circuit carrying capacity of the generator. The container must include a radiant cooling system capable of maintaining generator temperature in a range of ambient temperatures. The generator must be capable of operation in ambient temperatures of 15 degrees F to 100 degrees F. The generator fuel system must be capable of being refueled while on-line, may be connected to ship's power for heaters and battery chargers, but must not require any other fluid or system inputs from the ship. The generator and container must be suitable …
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)