Description
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice Page 3 of 14 Combined Synopsis/Solicitation Notice *= Required Field Combined Synopsis/Solicitation Notice Page 1 of 14 Solicitation Number: 36C10X26Q0059 Notice Type: Combined Synopsis/Solicitation Synopsis: COMBINED SYNOPSIS/SOLICITATION This is a combined synopsis/solicitation for commercial items prepared in accordance with (IAW) the format in Federal Acquisition Regulation (FAR) 12.202, Publicizing, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation will not be issued. Solicitation number 36C10X26Q0059 is issued for this combined synopsis/solicitation; this solicitation is being issued as a Request for Quote (RFQ). This combined synopsis/solicitation is issued under the agency's implementation of the Federal Acquisition Regulation (FAR) Overhaul, as adopted through agency class deviation. All applicable provisions, clauses, definitions, and procedures are those contained in the Overhaul text and the agency's implementation deviations. In the event of a conflict with the codified FAR, the adopted Overhaul text governs. The full text of provisions and clauses may be accessed electronically at https://www.acquisition.gov/far-overhaul/far-part-deviation-guide. Requirement Description: The Veterans Health Administration (VHA) Non-Expendable (NX) National Program has identified the Erbe® VIO 3, Electrosurgical Units, Argon-Enhanced Coagulation product line as a candidate for an Enterprise-wide (otherwise referred to as national ) single Requirements contract award. Electrosurgical Units (ESUs); Argon-Enhanced Coagulation (AEC) are advanced, energy based surgical systems used to perform precise tissue coagulation and devitalization across Veterans Affairs Medical Centers (VAMCs), particularly in operating rooms (OR), procedural suites, and endoscopy units. They deliver radiofrequency (RF) energy through specialized electrodes while directing a controlled flow of inert argon gas to create a conductive plasma at the tissue surface. This results in uniform, noncontact coagulation with minimal tissue penetration, improved visualization, and reduced bleeding. ESUs with AEC are designed to enhance surgical efficiency, improve hemostasis, and support consistent, replicable outcomes across a range of open, laparoscopic, and endoscopic procedures. These systems provide real-time, automated control of power delivery, argon flow, and activation mode, with integrated safety monitoring and configurable presets for procedure-specific use. They are optimized to increase clinical efficiency and reduce complications through precision energy delivery, reliable tissue effect profiles, and comprehensive safety interlocks. A single award Requirements contract will be awarded IAW all terms, conditions, provisions, specifications, and schedule of this solicitation herein.…
Classification
Contracting Office
Contacts