AI Summary
Description
THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. THE PURPOSE OF THIS ANNOUNCEMENT IS FOR MARKET RESEARCH PURPOSES ONLY. RESPONSE TO THIS ANNOUNCEMENT WILL BE USED BY THE GOVERNMENT TO MAKE APPROPRIATE ACQUISITION DECISIONS. A SUBSEQUENT SOLICITATION ANNOUNCEMENT MAY FOLLOW. RESPONSES TO THIS ANNOUNCEMENT WILL NOT BE CONSIDERED AS AN ADEQUATE RESPONSE TO ANY FUTURE ANNOUNCEMENT. The General Services Administration (GSA), Public Building Services (PBS) seeks vendor interests for Elevator Maintenance and Related Services at the following locations: Location 1: Kinneary US Courthouse, 85 Marconi Blvd., Columbus, OH 43215 Location 2: Bricker Federal Building, 200 N. High Street, Columbus, OH 43215 Location 3: Bricker Parking Garage, 200 N. High Street, Columbus, OH 43215 Location 4: Rice Federal Building & US Courthouse, 200 W. Second Street, Dayton, OH 45402 This project includes, but is not limited to, providing performance-based elevator maintenance services. The Contractor shall provide full elevator maintenance service, in compliance with the ASME Safety Code requirements, manufacturer's recommendations, Elevator Industry Field Employees' Safety Handbook, National Electrical Code, and all other applicable laws, regulations, rules, ordinances, codes, etc. Full maintenance service is defined as all services, repairs, inspections and testing necessary to maintain all elevators, appurtenances, and accessories in a fully operational mode at all times except for pre-scheduled downtime including all labor, parts and materials. In part, this includes maintenance and repair of door seals, light bulbs and lighting fixtures in elevator spaces (cars, hoist ways, tops and bottoms of cars, and pits), and maintaining acceptable ride quality which may require periodic evaluation and adjustment of guide rails. Reference is made to Section 8.6 of the ASME A17.1 Safety Code for Elevators and Escalators, and A18.1 Safety Standard for Platform Lifts and Stairway Chairlifts, which establishes requirements that must be adhered to. The maintenance contractor must provide all tools, equipment, supplies and personnel necessary for safely performing all tests required by the ASME A17.1 Safety Code for Elevators and Escalators, and A18.1 Safety Standard for Platform Lifts and Stairway Chairlifts, and the Authority Having Jurisdiction (AHJ). GSA is the AHJ. This includes inspections and tests required at six (6) month, one (1) year, three (3) year and five (5) year intervals, and any other tests determined as necessary by the CO or designee. All tests required by code will be conducted at no additional cost to the government regardless of when the testing is performed. Those wishing to identify their capability to provide the aforementioned services should respond to this announcement via email to natasha.cunningham@gsa.gov no later than Tuesday, October 6, 2026 at 3:00 PM (Eastern Standard Time). Interested parties should…
Classification
Place of Performance
Contracting Office
Contacts
Attachments (1)