AI Summary
Description
NOTICE OF INTENT TO SOLE SOURCE Contracting Opportunities Announcement Type : Special Notice Announcement Number: NB771030-26-01579 Subject: Swabian time tagging units for single photon counting Introduction This is a notice of intent, not a request for a quotation. A solicitation document will not be issued, and quotations will not be requested. Purpose The National Institute of Standards and Technology (NIST) intends to negotiate a firm-fixed priced purchase order on a sole source basis with Swabian Instruments USA, Inc. located at 4 Lucy St, Boston, MA 02125-2698. The purchase order will specifically procure two (2) TimeTaggerX that is manufactured by Swabian Instruments, GmbH located in Germany. Delivery shall occur within 30 days after receipt of an order. The TimeTaggerX will be used for single photon counting and will assist with NIST's research of developing a measurement test suite for quantum network component and protocol testing, verification, and characterization. Authority This acquisition is being conducted in accordance with FAR 12.102, citing the statutory authority 41 U.S.C. 1901 to solicit from only one source using simplified procedures. The North American Industry Classification System (NAICS) code for this acquisition is 334515 – Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals with the small business size standard of 750 Employees. Description NIST requires a quantity of two (2) Swabian Time Tagger X Systems (and software). The Swabian Time Tagger X System & Software time tagging unit for single photon counting shall consist of the following specifications: 5 channel streaming time tagging system 2 ps resolution (rms jitter) A channel deadtime of less than 1.5 ns Full software package, to include development kit with programming examples for implementation into Matlab, Python, Labview and C++, and lifetime software and firmware updates. Software needs to be compatible with the software suite developed at NIST on the existing Time Tagger X and Time Tagger 20 manufactured by Swabian. Sole Source Determination The sole source determination is based on the following: The National Institute of Standards and Technology requires two Swabian X time tagging units to be implemented into our quantum component measurement suite. In order to perform most state-of-the art measurements of most state-of-the art single photon devices, such as detectors and sources, the required dedicated time tagging unit shall allow determination of a single photon's arrival time. This time tagging unit shall allow NIST to characterize afterpulsing, dark noise and source response times. All these measurements have already been implemented in a similar system also using a Swabian X time tagger, and an extensive software and data acquisition library has been written by NIST researchers. Results would not be comparable to results produced from experiments using other time tagging units not produced by Swabian. The Swabian…
Classification
Contracting Office
Contacts