COFFMAN ENGINEERS, INC.
UEI: GAK3VQRQJ8R5
$6.3M
Obligations · USAspending
Actions Dec '17 – Jul '24
7
Contract awards · USAspending
—
SAM.gov award notices · 12 mo
Top agencies
By obligations · USAspending, all years
- Department of Defense$6.3M · 7 awards
Top NAICS
By obligations · USAspending, all years
- 541330 Engineering Services$6.3M
Recent awards
Latest contract actions by start date · USAspending
| Award | Agency | Start | Amount |
|---|---|---|---|
| FA500424C0012 | Department of the Air Force | 07/11/2024 | $550K |
| FA500424C0004 | Department of the Air Force | 03/15/2024 | $3.1M |
| FA500423C0005 | Department of the Air Force | 03/09/2023 | $517K |
| FA500423C0004 | Department of the Air Force | 03/09/2023 | $511K |
| FA500422C0021 | Department of the Air Force | 07/20/2022 | $284K |
| FA500422C0004 | Department of the Air Force | 11/19/2021 | $433K |
| FA500418CC001 | Department of the Air Force | 12/12/2017 | $927K |
Subcontracts received
Subcontracts reported by primes (FFATA) · first tier only, self-reported, may be incomplete
$1.0M
Received · FY2025–FY2027
$1.0M
Received · all years
2
Subawards
1
Prime
Top primes
| Prime contractor | Total |
|---|---|
| STAMPEDE VENTURES, INC. | $1.0M |
Most recent
- $698KQUALIFIED FIRE PROTECTION SERVICES: • COMPLETE THE QFPE SERVICES AND PROVIDE THE DESIGN IN ACCORDANCE WITH APPLICABLE UFC’S, THE 2024 EDITIONS OF IBC AND IFC, THE 2022 EDITION OF NFPA 72 AND THE 2024 EDITION OF NFPA 101 AS WELL AS ALL APPLICABLE REFERENCED STANDARDS THEREIN AND THE ACTIVITIES, TASKS AND DELIVERABLES OUTLINED. 4.5.2 FIRE PROTECTION ENGINEERING SERVICES: • EVALUATION OF EXISTING FACILITY FOR COMPLIANCE WITH CURRENT UFC AND CODES RELATED TO LIFE SAFETY AND MEANS OF EGRESS. FIRE PROTECTION ENGINEERING WILL PROVIDE A FIRE PROTECTION DESIGN ANALYSIS WITH LIFE SAFETY DRAWINGS INCLUDING IDENTIFICATION OF ANY EXISTING DEFICIENCIES. • PROVIDE REQUIRED QFPE SERVICES IN ACCORDANCE WITH UFC 3-600-01 FOR THE PROJECT. • DEVELOP FIRE ALARM AND MASS NOTIFICATION SYSTEM SHOP DRAWINGS IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 72 FOR CONSTRUCTION. • DEVELOP REQUIRED FIRE ALARM AND MASS NOTIFICATION SYSTEM CALCULATIONS. 4.5.3 MECHANICAL ENGINEERING SERVICES: • DEMOLITION OF LIFT STATION PUMPS AND ASSOCIATED CONTROLS. • SPECIFICATION OF NEW PUMPS AND PACKAGED CONTROLS. • SPECIFICATION OF PIPING AND VALVING ASSOCIATED WITH NEW PUMPS. • PROVIDE CONSTRUCTION VENTILATION (CV) SPECIFICATION THAT ACCOUNTS FOR MAINTAINING PROPER HVAC IN ADJACENT SPACES AND A NEGATIVELY PRESSURIZED CONSTRUCTION ZONE DURING THE CONSTRUCTION. • ASSIST IN THE PREPARATION OF AN INFECTION CONTROL RISK ASSESSMENT 2.0 FORM. WE WILL COLLABORATE WITH FACILITY REPRESENTATIVES AND THE REST OF THE DESIGN AND CONSTRUCTION TEAM TO FINALIZE THE FORM. • REVIEW OF UP TO 3 TAB REPORTS (PRE-CV SETUP, POST-CV SETUP, AND POST-CV TAKE DOWN) REQUIRED IN THE SPECIFICATIONS. 4.5.4 STRUCTURAL ENGINEERING SERVICES: • DESIGN OF SUPPORTS FOR MAJOR PIECES OF EQUIPMENT: WALL MOUNTED CABINETS, PANELBOARDS, SWITCHBOARDS AND MOTOR CONTROL CENTERS. • DESIGN OF GRAVITY SUPPORTS FOR MECHANICAL AND ELECTRICAL CONDUIT AND NON-SPRINKLER PIPING, AS NEEDED. • ATFP REINFORCEMENT AS REQUIRED. 4.5.5 CYBERSECURITY ENGINEERING SERVICES: THE SCOPE FOR CYBERSECURITY DESIGN REQUIREMENTS INCLUDES IMPLEMENTING CYBERSECURITY FEATURES IN ALL CONTROL SYSTEMS ACCORDING TO UNIFIED FACILITIES CRITERIA 4-010-06, CYBERSECURITY FOR FACILITY RELATED CONTROL SYSTEMS, AND UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS) 25 05 11 – CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS, AND AS NEEDED BY INSTALLATION POLICY. FRCS CYBERSECURITY DESIGN SERVICES INCLUDE COORDINATION WITH CYBERSECURITY STAKEHOLDERS, DOCUMENTATION OF CONFIDENTIALITY, INTEGRITY, AND AVAILABILITY (C-I-A) IMPACT LEVELS IDENTIFIED BY SYSTEM OWNER (SO) FOR DEVELOPMENT OF CONTROL CORRELATION IDENTIFIERS (CCIS) LIST, IDENTIFY AUTHORITY TO OPERATE (ATO) STATUS, AND WILL BE PERFORMED BY A COFFMAN IAM LEVEL II CERTIFIED PROFESSIONAL OUTLINED IN DOD 8570/8140 INFORMATION ASSURANCE WORKFORCE IMPROVEMENT PROGRAM. AS SUCH, COFFMAN WILL INCLUDE CYBERSECURITY DESIGN FOR: • FIRE AND LIFE SAFETY FACILITY-RELATED CONTROL SYSTEMS TO INCLUDE THE FIRE ALARM AND MASS NOTIFICATION SYSTEM WITH A L-M-M C-I-A RATING. • COFFMAN WILL PRODUCE THE FOLLOWING DELIVERABLES BY THE END OF THE DESIGN PROCESS: A BASIS OF DESIGN (BOD), CONTROL CORRELATION IDENTIFIER (CCI LIST), AND UFGS 25 05 11 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS SPECIFICATION FOR EACH IDENTIFIED FRCS SYSTEM. 4.5.6 ELECTRICAL ENGINEERING SERVICES: • EVALUATION OF POWER TO EXISTING FIRE ALARM SYSTEM, EGRESS PATH LIGHTING CONTROLS AND SUMP PUMP SYSTEM TO DETERMINE ELECTRICAL MODIFICATIONS REQUIRED BY THIS PROJECT. • INVESTIGATION OF EXISTING FACILITY ELECTRICAL DISTRIBUTION SYSTEM AND SUITABILITY TO SUPPORT THIS PROJECT. • INVESTIGATION OF EXISTING FACILITY GENERATOR SYSTEM AND SUITABILITY TO SUPPORT THIS PROJECT. • AS-BUILTING AND LOAD CALCULATION OF THE GENERATOR SYSTEM. • INVESTIGATION OF EXISTING RAINWATER/CONDENSATE SUMP PUMP SYSTEM, AND ELECTRICAL SUPPORT FOR THE REPLACEMENT SYSTEM. • IF ANY EGRESS PATH LIGHTING CONTROL SYSTEMS REQUIRE MODIFICATION DUE TO CURRENT FIRE ALARM CODES, DESIGN OF THOSE
- $312KENGINEERING SERVICES: SITE REPORT. DESIGN ANALYSIS. 65% & 100% DESIGN PACKAGES.