PHOENIX FIRE PROTECTION INC
UEI: K21HJ3JTATV8
—
Obligations · USAspending
—
Contract awards · USAspending
—
SAM.gov award notices · 12 mo
Subcontracts received
Subcontracts reported by primes (FFATA) · first tier only, self-reported, may be incomplete
$1.3M
Received · FY2025–FY2027
$1.3M
Received · all years
3
Subawards
3
Primes
Top primes
| Prime contractor | Total |
|---|---|
| CHICKASAW DEFENSE GROUP, LLC | $1.0M |
| STAMPEDE VENTURES, INC. | $282K |
| XL CONSTRUCTION LLC | $11K |
Most recent
- $282K• SUBMITTALS, COMPLETE SHOP DRAWINGS. • HYDRAULIC CALCULATIONS. FIRE PUMP TEST REPORT TO BE PROVIDED BY THE FACILITY. • SEQUENCE AND LOGISTICS PLAN. • SPRINKLER SYSTEMS TO REMAIN IN SERVICE. • WORK TO BE PERFORMED IN 2 PHASES. • IDENTIFY, CUT, CAP, MAKE SAFE. DEMO AND REMOVAL BY OTHERS. • FOR PHASE 1, INSTALL NEW MAIN, BRANCH LINES, AND SPRINKLERS TO PROVIDE PROPER PROTECTION. CONNECT NEW MAIN TO EXISTING PHASE 2 MAIN TEMPORARILY AND CONNECT NEW FEED MAIN TO EXISTING FEED MAIN IN CORRIDOR. TIE IN FOR FINAL FEED MAIN TO BE COMPLETED IN PHASE 2. • FOR PHASE 2, INSTALL NEW MAIN, BRANCH LINES AND SPRINKLERS TO PROVIDE PROPER PROTECTION. INSTALL NEW FEED MAIN FROM THE VALVE IN THE STAIR WELL TO RECONNECT TO THE NEW FEED MAIN INSTALLED UNDER PHASE 1. • INSTALL NEW HEADER IN THE STAIRWELL WITH 4” WELDED OUTLETS AND PROVIDE (1) NEW CONTROL VALVE ASSEMBLY TO FEED OUR NEW ZONE. THE OTHER (2) EXISTING CONTROL VALVE ASSEMBLIES TO REMAIN AND WILL BE RECONNECTED TO THE NEW HEADER OUTLETS. • NEW PURGE IN THE MECHANICAL ROOM AS SHOWN. DRAIN TO TERMINATE AT PLUMBING DRAIN IN THE MECHANICAL ROOM OR ADJACENT SPACE. NO PIPING TO EXTERIOR. PLUMBING CONNECTIONS BY OTHERS IF REQUIRED. • NEW SYSTEM DRAIN TO TERMINATE IN THE STAIRWELL AT THE EXISTING MAIN DRAIN RISER. • NEW MAIN AND BRANCH LINES TO BE ROUGHED IN PRIOR TO CEILING FRAMING. • NEW MAIN TO BE SCHEDULE 40 BLACK STEEL WITH ROLL-GROOVED ENDS AND NEW BRANCH LINES TO BE SCHEDULE 40 BLACK STEEL WITH ROLL-GROOVED OR THREADED ENDS. • NEW SPRINKLERS TO BE SEMI-RECESSED WITH CHROME PLATES, HORIZONTAL SIDE WALL SPRINKLERS WITH CHROME PLATES, AND BRASS UPRIGHTS IN EXPOSED CEILINGS. • NEW SPRINKLERS TO BE QUICK RESPONSE. • FLEXIBLE COUPLINGS AT EXPANSION JOINTS. • HYDROSTATIC TESTING AND ASSISTING THE FIRE ALARM SUB IN TESTING DEVICES ASSOCIATED WITH THE SPRINKLER SYSTEM. • WRAP AROUND PIPE LABELS ON NEW MAIN AND BRANCH LINES. • FIRE STOPPING AND MINERAL WOOL FOR NEW PENETRATIONS IN RATED WALLS. • WORK SHALL COMPLY WITH BID DOCUMENTS, NFPA 13, UFC 3-600-01, AND THE FACILITY FIRE MARSHALS REQUIREMENTS.
- $11KFIRE PROTECTION SERVICE
- $1.0MFIRE PROTECTION INSTALLATION, SPRINKLERS